دورية أكاديمية

Evaluation of surface roughness and hardness of different glass ionomer cements.

التفاصيل البيبلوغرافية
العنوان: Evaluation of surface roughness and hardness of different glass ionomer cements.
المؤلفون: Bala O; University of Gazi, Faculty of Dentistry, Department of Operative & Restorative Dentistry, Ankara, TURKIYE., Arisu HD, Yikilgan I, Arslan S, Gullu A
المصدر: European journal of dentistry [Eur J Dent] 2012 Jan; Vol. 6 (1), pp. 79-86.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Thieme Country of Publication: Germany NLM ID: 101303672 Publication Model: Print Cited Medium: Internet ISSN: 1305-7464 (Electronic) NLM ISO Abbreviation: Eur J Dent Subsets: PubMed not MEDLINE
أسماء مطبوعة: Publication: [2019]- : [Stuttgart] : Thieme
Original Publication: Ankara : Dental Investigations Society
مستخلص: Objectives: The aim of this study was to evaluate surface roughness and hardness of a nanofiller GIC, a resin-modified GIC, three conventional GICs, and a silver-reinforced GIC.
Methods: For each material, 11 spcecimens were prepared and then stored in distilled water at 37 °C for 24 h. The surface roughness of 5 specimens was measured using a surface profilometer before polishing and after polishing with coarse, medium, fine, superfine aluminum oxide abrasive Sof-Lex discs respectively. The hardness of the upper surfaces of the remaining 6 specimens was measured with a Vickers microhardness measuring instrument.
Results: All tested GICs showed lower surface roughness values after the polishing procedure. Surface finish of nanofiller GIC was smoother than the other tested GICs after polishing. This was followed by resin-modified GIC, Fuji II LC; then silver-reinforced GIC, Argion Molar, conventional GICs, Aqua Ionofil Plus, Fuji IX, and Ionofil Molar, respectively. The result of the hardness test indicated that the microhardness value of silver-reinforced GIC was greater than that of the other GICs. When the hardness values of all tested GICs were compared, the differences between materials (except Aqua Ionofil Plus with Ionofil Molar and Ketac N100 with Fuji II LC (P>.05)) were found statistically significant (P<.05).
Conclusions: According to the results of this study, it can be concluded that the differences in the composition of GICs may affect their surface roughness and hardness.
References: J Prosthet Dent. 1984 Aug;52(2):182-9. (PMID: 6590836)
J Oral Rehabil. 2002 Sep;29(9):864-71. (PMID: 12366542)
Br Dent J. 1992 Apr 11;172(7):279-82. (PMID: 1445523)
J Oral Rehabil. 1991 Mar;18(2):163-8. (PMID: 2037939)
Dent Mater. 2003 Jan;19(1):12-8. (PMID: 12498891)
J Oral Rehabil. 2007 Jan;34(1):68-76. (PMID: 17207080)
Pediatr Dent. 1998 Mar-Apr;20(2):93-100. (PMID: 9566012)
Oper Dent. 1996 Mar-Apr;21(2):53-8. (PMID: 8957918)
Dent Mater. 2000 Mar;16(2):129-38. (PMID: 11203534)
J Oral Rehabil. 1998 Jun;25(6):456-61. (PMID: 9687119)
J Am Dent Assoc. 1975 Jul;91(1):101-6. (PMID: 166101)
J Dent Res. 1991 Oct;70(10):1358-61. (PMID: 1939829)
J Dent. 2000 Jul;28(5):367-73. (PMID: 10785304)
J Dent Res. 1997 Apr;76(4):883-94. (PMID: 9126185)
J Oral Rehabil. 2003 Feb;30(2):218-24. (PMID: 12535151)
Dent Mater. 2002 Sep;18(6):454-62. (PMID: 12098574)
Dent Mater. 1999 Nov;15(6):421-5. (PMID: 10863443)
J Adhes Dent. 2002 Spring;4(1):73-80. (PMID: 12071632)
Dent Mater. 1985 Dec;1(6):225-7. (PMID: 2420667)
J Mater Sci Mater Med. 2003 Oct;14(10):869-73. (PMID: 15348524)
Dent Mater. 1991 Jul;7(3):151-4. (PMID: 1813336)
J Appl Oral Sci. 2009 Nov-Dec;17(6):544-54. (PMID: 20027424)
J Nihon Univ Sch Dent. 1997 Sep;39(3):123-7. (PMID: 9354026)
Oper Dent. 2000 Sep-Oct;25(5):382-7. (PMID: 11203846)
Biomaterials. 1998 Mar;19(6):521-7. (PMID: 9645558)
Singapore Dent J. 2004 Dec;26(1):39-43. (PMID: 15736840)
J Oral Rehabil. 2003 Jul;30(7):714-9. (PMID: 12791157)
Dent Update. 2001 Dec;28(10):486-91. (PMID: 11862849)
Dent Mater. 2003 Jun;19(4):286-90. (PMID: 12686292)
Oper Dent. 2001 Jul-Aug;26(4):343-8. (PMID: 11504433)
Clin Oral Implants Res. 1996 Sep;7(3):201-11. (PMID: 9151584)
J Prosthet Dent. 1988 Feb;59(2):137-41. (PMID: 3278094)
فهرسة مساهمة: Keywords: Glass ionomer cement; hardness; surface roughness
تواريخ الأحداث: Date Created: 20120110 Date Completed: 20121002 Latest Revision: 20220409
رمز التحديث: 20240829
مُعرف محوري في PubMed: PMC3252813
PMID: 22229011
قاعدة البيانات: MEDLINE