دورية أكاديمية

Comparison and effects of two different airway occlusion times during measurement of maximal inspiratory pressure in adult intensive care unit neurological patients.

التفاصيل البيبلوغرافية
العنوان: Comparison and effects of two different airway occlusion times during measurement of maximal inspiratory pressure in adult intensive care unit neurological patients.
عنوان ترانسليتريتد: Comparação e efeitos de dois diferentes tempos de oclusão da via aérea durante a mensuração da pressão inspiratória máxima em pacientes neurológicos na unidade de terapia intensiva de pacientes adultos.
المؤلفون: Pinheiro Filho GR; Curso de Fisioterapia em UTI, Universidade Federal da Bahia - UFBA, Salvador, BA, Brasil., Reis HF; Escola Bahiana de Medicina e Saúde Pública, Salvador, BA, Brasil., Almeida ML; Hospital Geral do Estado, Salvador, BA, Brasil., Andrade Wde S; Hospital Geral do Estado - HGE, Salvador, BA, Brasil., Rocha RL; Universidade Federal da Bahia - UFBA, Salvador, BA, Brasil., Leite PA; Hospital Geral do Estado, Salvador, BA, Brasil.
المصدر: Revista Brasileira de terapia intensiva [Rev Bras Ter Intensiva] 2010 Mar; Vol. 22 (1), pp. 33-9.
نوع المنشور: Journal Article
اللغة: English; Portuguese
بيانات الدورية: Publisher: Associação de Medicina Intensiva Brasileira Country of Publication: Brazil NLM ID: 9506692 Publication Model: Print Cited Medium: Print ISSN: 0103-507X (Print) Linking ISSN: 0103507X NLM ISO Abbreviation: Rev Bras Ter Intensiva Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: [Rio de Janeiro] : Associação de Medicina Intensiva Brasileira,
مستخلص: Objective: To verify if the maximal inspiratory pressure values with 40 seconds occlusion time are greater than with the 20 seconds occlusion time, and the impacts on the following patient's physiological variables: respiratory rate, pulse oxygen saturation, heart rate and blood pressure, before and after the measurements.
Methods: This was a transversal prospective randomized study. Fifty-one patients underwent maximal inspiratory pressure measurement, measured by one single investigator. The manometer was calibrated before each measurement, and then connected to the adapter and this to the unidirectional valve inspiratory branch for 20 or 40 seconds.
Results: The values with 40 seconds occlusion (57.6 ± 23.4 cmH2O) were significantly higher than the measurements taken with 20 seconds occlusion (40.5 ± 23.4 cmH2O; p=0.0001). The variables changes between the before and after measurement respiratory and hemodynamic parameters monitoring showed: heart rate variation for the 20 seconds occlusion 5.13 ± 8.56 beats per minute and after 40 seconds occlusion 7.94 ± 12.05 beats per minute (p = 0.053), versus baseline. The mean blood pressure change for 20 seconds occlusion was 9.29 ± 13.35 mmHg and for 40 seconds occlusion 15.52 ± 2.91 mmHg (p=0.021). The oxygen saturation change for 20 seconds occlusion was 1.66 ± 12.66%, and for 40 seconds 4.21 ± 5.53% (p=0.0001). The respiratory rate change for 20 seconds occlusion was 6.68 ± 12.66 movements per minute and for 40 seconds 6.94 ± 6.01 (p=0.883).
Conclusion: The measurement of maximal inspiratory pressure using a longer occlusion (40 seconds) produced higher values, without triggering clinically significant stress according to the selected variables.
تواريخ الأحداث: Date Created: 20141011 Date Completed: 20151026 Latest Revision: 20141011
رمز التحديث: 20240628
PMID: 25303697
قاعدة البيانات: MEDLINE