دورية أكاديمية

Autograft Valve-Sparing Root Replacement for Late Ross Failure during Quadruple-Valve Surgery.

التفاصيل البيبلوغرافية
العنوان: Autograft Valve-Sparing Root Replacement for Late Ross Failure during Quadruple-Valve Surgery.
المؤلفون: Goldstone AB; Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, CA, USA., Jensen CW; Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, CA, USA., Bilbao MS; Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, CA, USA., Woo YJ; Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, CA, USA.
المصدر: Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia [Ann Thorac Cardiovasc Surg] 2017 Dec 20; Vol. 23 (6), pp. 313-315. Date of Electronic Publication: 2017 Oct 17.
نوع المنشور: Case Reports; Journal Article
اللغة: English
بيانات الدورية: Publisher: Japanese Editorial Committee of Annals of Thoracic and Cardiovascular Surgery Country of Publication: Japan NLM ID: 9703158 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 2186-1005 (Electronic) Linking ISSN: 13411098 NLM ISO Abbreviation: Ann Thorac Cardiovasc Surg Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Tokyo : Japanese Editorial Committee of Annals of Thoracic and Cardiovascular Surgery,
مواضيع طبية MeSH: Device Removal*, Aortic Aneurysm/*surgery , Aortic Valve Insufficiency/*surgery , Blood Vessel Prosthesis Implantation/*methods , Heart Valve Prosthesis Implantation/*methods , Mitral Valve Annuloplasty/*methods , Mitral Valve Insufficiency/*surgery , Pulmonary Valve Insufficiency/*surgery , Tricuspid Valve Insufficiency/*surgery, Aged ; Aortic Aneurysm/diagnostic imaging ; Aortic Aneurysm/etiology ; Aortic Valve Insufficiency/diagnostic imaging ; Aortic Valve Insufficiency/etiology ; Aortic Valve Insufficiency/physiopathology ; Autografts ; Bioprosthesis ; Blood Vessel Prosthesis ; Blood Vessel Prosthesis Implantation/adverse effects ; Blood Vessel Prosthesis Implantation/instrumentation ; Heart Valve Prosthesis ; Heart Valve Prosthesis Implantation/adverse effects ; Heart Valve Prosthesis Implantation/instrumentation ; Humans ; Male ; Mitral Valve Annuloplasty/adverse effects ; Mitral Valve Annuloplasty/instrumentation ; Mitral Valve Insufficiency/diagnostic imaging ; Mitral Valve Insufficiency/etiology ; Mitral Valve Insufficiency/physiopathology ; Pulmonary Valve Insufficiency/diagnostic imaging ; Pulmonary Valve Insufficiency/etiology ; Pulmonary Valve Insufficiency/physiopathology ; Treatment Failure ; Tricuspid Valve Insufficiency/diagnostic imaging ; Tricuspid Valve Insufficiency/etiology ; Tricuspid Valve Insufficiency/physiopathology
مستخلص: Approximately 25% of patients require reoperation within 15 yrs of a Ross procedure. Increasing experience with valve-sparing root replacement (VSRR) has led some surgeons to spare the autograft valve. Here, we demonstrate that all valves can be surgically repaired or replaced safely during autograft VSRR. As more patients are considered for this operation, coexistent mitral, tricuspid, and pulmonic valve dysfunction should not preclude salvage of the autograft valve, nor should autograft leaflet prolapse.
References: J Card Surg. 2013 Sep;28(5):496-9. (PMID: 23782261)
Eur J Cardiothorac Surg. 2016 Feb;49(2):507-12; discussion 512-3. (PMID: 25736279)
J Thorac Cardiovasc Surg. 2015 Nov;150(5):1132-7. (PMID: 26395045)
Eur J Cardiothorac Surg. 2016 Feb;49(2):514-9; discussion 519. (PMID: 25755185)
J Thorac Cardiovasc Surg. 2015 Nov;150(5):1138-9. (PMID: 26546201)
فهرسة مساهمة: Keywords: Ross procedure; aortic valve; valve-sparing root replacement
تواريخ الأحداث: Date Created: 20171020 Date Completed: 20181211 Latest Revision: 20181211
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC5738454
DOI: 10.5761/atcs.cr.16-00264
PMID: 29046487
قاعدة البيانات: MEDLINE
الوصف
تدمد:2186-1005
DOI:10.5761/atcs.cr.16-00264