دورية أكاديمية

Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the Collapsed Cone Convolution algorithm for head and neck cancers.

التفاصيل البيبلوغرافية
العنوان: Dosimetric and Monte Carlo verification of jaws-only IMRT plans calculated by the Collapsed Cone Convolution algorithm for head and neck cancers.
المؤلفون: Tai DT; Department of Radiation Oncology, Dong Nai General Hospital, Bien Hoa 810000, Viet Nam.; Faculty of Physics & Engineering Physics, VNUHCM-University of Science, Ho Chi Minh 749000, Viet Nam.; Faculty of Medicine, Nguyen Tat Thanh University, Ho Chi Minh 702000, Viet Nam., Oanh LT; Faculty of Medicine, Nguyen Tat Thanh University, Ho Chi Minh 702000, Viet Nam.; Faculty of Physics & Engineering Physics, VNUHCM-University of Science, Ho Chi Minh 749000, Viet Nam., Son ND; Chi Anh Medical Technology Co., Ltd., Ho Chi Minh 717066, Viet Nam., Loan TTH; Faculty of Physics & Engineering Physics, VNUHCM-University of Science, Ho Chi Minh 749000, Viet Nam., Chow JCL; Department of Radiation Oncology, University of Toronto, Toronto M5T 1P5, Canada.; Princess Margaret Cancer Centre, University Health Network, Toronto M5G 1Z5, Canada.
المصدر: Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology [Rep Pract Oncol Radiother] 2019 Jan-Feb; Vol. 24 (1), pp. 105-114. Date of Electronic Publication: 2018 Nov 28.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Via Medica Country of Publication: Poland NLM ID: 100885761 Publication Model: Print-Electronic Cited Medium: Print ISSN: 1507-1367 (Print) Linking ISSN: 15071367 NLM ISO Abbreviation: Rep Pract Oncol Radiother Subsets: PubMed not MEDLINE
أسماء مطبوعة: Publication: 2021- : Gdańsk, Poland : Via Medica
Original Publication: Poznań : Greatpoland Cancer Center and Polish Society of Radiation Oncology, 1998-
مستخلص: Aim: The aim of this study is to verify the Prowess Panther jaws-only intensity modulated radiation therapy (JO-IMRT) treatment planning (TP) by comparing the TP dose distributions for head-and-neck (H&N) cancer with the ones simulated by Monte Carlo (MC).
Background: To date, dose distributions planned using JO-IMRT for H&N patients were found superior to the corresponding three-dimensional conformal radiotherapy (3D-CRT) plans. Dosimetry of the JO-IMRT plans were also experimentally verified using an ionization chamber, MapCHECK 2, and Octavius 4D and good agreements were shown.
Materials and Methods: Dose distributions of 15 JO-IMRT plans of nasopharyngeal patients were recalculated using the EGSnrc Monte Carlo code. The clinical photon beams were simulated using the BEAMnrc. The absorbed dose to patients treated by fixed-field IMRT was computed using the DOSXYZnrc. The simulated dose distributions were then compared with the ones calculated by the Collapsed Cone Convolution (CCC) algorithm on the TPS, using the relative dose error comparison and the gamma index using global methods implemented in PTW-VeriSoft with 3%/3 mm, 2%/2 mm, 1%/1 mm criteria.
Results: There is a good agreement between the MC and TPS dose. The average gamma passing rates were 93.3 ± 3.1%, 92.8 ± 3.2%, 92.4 ± 3.4% based on the 3%/3 mm, 2%/2 mm, 1%/1 mm criteria, respectively.
Conclusions: According to the results, it is concluded that the CCC algorithm was adequate for most of the IMRT H&N cases where the target was not immediately adjacent to the critical structures.
References: Med Phys. 2003 Feb;30(2):144-57. (PMID: 12607832)
Med Dosim. 2001 Summer;26(2):157-68. (PMID: 11444518)
Med Phys. 2007 Jan;34(1):307-14. (PMID: 17278516)
Int J Radiat Oncol Biol Phys. 2006 Mar 1;64(3):968-77. (PMID: 16458782)
Med Phys. 2003 May;30(5):979-85. (PMID: 12773007)
Phys Med Biol. 2000 Sep;45(9):2483-95. (PMID: 11008950)
World J Radiol. 2016 Mar 28;8(3):255-67. (PMID: 27027225)
Int J Radiat Oncol Biol Phys. 2003 May 1;56(1):58-68. (PMID: 12694824)
Med Phys. 1995 May;22(5):503-24. (PMID: 7643786)
Phys Med. 2017 Jun;38:148-152. (PMID: 28571708)
Phys Med Biol. 2005 Jul 21;50(14):3375-92. (PMID: 16177516)
Med Phys. 1999 Oct;26(10):2133-43. (PMID: 10535630)
Med Phys. 2006 Oct;33(10):3666-79. (PMID: 17089832)
J Cancer Res Ther. 2018 Jan-Mar;14(2):351-356. (PMID: 29516918)
فهرسة مساهمة: Keywords: CERR; DOSCTP; Intensity-modulated radiation therapy (IMRT); Jaws-only IMRT (JO-IMRT); Monte Carlo simulation (MC); Quality assurance (QA)
تواريخ الأحداث: Date Created: 20181212 Latest Revision: 20220330
رمز التحديث: 20240628
مُعرف محوري في PubMed: PMC6262183
DOI: 10.1016/j.rpor.2018.11.004
PMID: 30532658
قاعدة البيانات: MEDLINE
الوصف
تدمد:1507-1367
DOI:10.1016/j.rpor.2018.11.004