دورية أكاديمية

ACL reconstruction with quadriceps tendon graft and press-fit fixation versus quadruple hamstring graft and interference screw fixation - a matched pair analysis after one year follow up.

التفاصيل البيبلوغرافية
العنوان: ACL reconstruction with quadriceps tendon graft and press-fit fixation versus quadruple hamstring graft and interference screw fixation - a matched pair analysis after one year follow up.
المؤلفون: Akoto R; Sports Clinic Cologne at Cologne Merheim Medical Center, Cologne, University of Witten/Herdecke, Ostmerheimerstraße 200, D-51109, Cologne, Germany.; Department of Trauma and Orthopedic Surgery, University of Witten/Herdecke, Cologne Merheim Medical Center, Cologne, Germany.; Department of Trauma and Reconstructive Surgery, Asklepios Clinic St. Georg, Hamburg, Germany., Albers M; Sports Clinic Cologne at Cologne Merheim Medical Center, Cologne, University of Witten/Herdecke, Ostmerheimerstraße 200, D-51109, Cologne, Germany., Balke M; Sports Clinic Cologne at Cologne Merheim Medical Center, Cologne, University of Witten/Herdecke, Ostmerheimerstraße 200, D-51109, Cologne, Germany., Bouillon B; Department of Trauma and Orthopedic Surgery, University of Witten/Herdecke, Cologne Merheim Medical Center, Cologne, Germany., Höher J; Sports Clinic Cologne at Cologne Merheim Medical Center, Cologne, University of Witten/Herdecke, Ostmerheimerstraße 200, D-51109, Cologne, Germany. hoeher@sporttrauma-koeln.de.
المصدر: BMC musculoskeletal disorders [BMC Musculoskelet Disord] 2019 Mar 14; Vol. 20 (1), pp. 109. Date of Electronic Publication: 2019 Mar 14.
نوع المنشور: Comparative Study; Journal Article
اللغة: English
بيانات الدورية: Publisher: BioMed Central Country of Publication: England NLM ID: 100968565 Publication Model: Electronic Cited Medium: Internet ISSN: 1471-2474 (Electronic) Linking ISSN: 14712474 NLM ISO Abbreviation: BMC Musculoskelet Disord Subsets: MEDLINE
أسماء مطبوعة: Original Publication: London : BioMed Central, [2000-
مواضيع طبية MeSH: Bone Screws* , Internal Fixators*, Anterior Cruciate Ligament Reconstruction/*methods , Hamstring Muscles/*transplantation , Quadriceps Muscle/*transplantation , Tendons/*transplantation, Adult ; Anterior Cruciate Ligament Injuries/diagnosis ; Anterior Cruciate Ligament Injuries/surgery ; Anterior Cruciate Ligament Reconstruction/instrumentation ; Anterior Cruciate Ligament Reconstruction/trends ; Cohort Studies ; Female ; Follow-Up Studies ; Humans ; Male ; Matched-Pair Analysis ; Retrospective Studies ; Time Factors ; Tissue Donors ; Tissue Transplantation/methods ; Young Adult
مستخلص: Background: The objective of the study was to compare the results of a primary anterior cruciate ligament reconstruction (ACLR) using the press-fit fixation technique for a quadriceps tendon (QT) graft to a standard quadrupled hamstring (HT) graft with interference screw fixation.
Methods: A retrospective cohort study with a 12-month follow up provided data for 92 patients. Exclusion criteria were accompanying ligament injuries and contralateral ACL injury. Patients who suffered a graft failure, which was defined as a side-to-side difference of > 3 mm, or infection were rated 'D' according to the IKDC and excluded from further evaluation. Forty-six patients underwent primary ACLR using the press-fit fixation technique for autologous bone QT graft. These patients were matched in terms of age, gender, accompanying meniscus tear and cartilage injury to 46 patients who underwent standard HT graft with interference screw fixation. Patients were evaluated according to the Lachman test, Pivot-Shift test, IKDC score, Tegner score, Rolimeter measurements, one-leg hop test, thigh circumference and donor side morbidity.
Results: No significant differences in Tegner score (p = 0.9), subjective or objective IKDC score (p = 0.9;p = 0.6), knee stability (Lachman Test p = 0.6; Pivot-Shift Test p = 0.4; Side-to-Side Difference p = 0.4), functioning testing (One-Leg Hop Test p = 0.6; Thigh Circumference p = 0.4) or donor side morbidity (p = 0.4) were observed at the follow up. The Lachman test was negative for 85% of the QT group and 83% of the HT group. The Pivot Shift Test was negative for 80% of the QT group and 85% of the HT group. The mean side-to-side difference was 1.6 ± 0 .2mm in both groups. The one-leg hop test revealed a collateral-side jumping distance of 96.2 ± 8.5% for the QT group and 95.5 ± 8.5% for the HT group. The thigh circumference of the injured leg was 98.3 ± 3.0% on the uninjured side in the QT group and 99.7 ± 3.0% in the HT group. A knee walking test resulted in no discomfort for 90% of the QT group and 85% of the HT group. The graft failure rate was 7.3% in the QT group and 9.8% in the HT group.
Conclusion: QT grafts fixated using the press-fit technique are a reliable alternative for primary ACL surgery.
References: Am J Sports Med. 2000 May-Jun;28(3):328-35. (PMID: 10843123)
Arthroscopy. 2001 Nov-Dec;17(9):971-80. (PMID: 11694930)
Orthop Clin North Am. 2003 Jan;34(1):49-64. (PMID: 12735201)
Knee Surg Sports Traumatol Arthrosc. 2005 May;13(4):248-55. (PMID: 15690197)
Arch Orthop Trauma Surg. 2006 May;126(4):265-70. (PMID: 16172862)
Knee Surg Sports Traumatol Arthrosc. 2007 Nov;15(11):1284-92. (PMID: 17721778)
Clin Orthop Relat Res. 2008 Jan;466(1):198-204. (PMID: 18196393)
Arthroscopy. 2009 Feb;25(2):137-44. (PMID: 19171272)
Strategies Trauma Limb Reconstr. 2009 Oct;4(2):73-9. (PMID: 19697105)
Arthroscopy. 2009 Dec;25(12):1408-14. (PMID: 19962067)
Arch Orthop Trauma Surg. 2010 Aug;130(8):985-92. (PMID: 20094723)
Unfallchirurg. 2010 Aug;113(8):629-34. (PMID: 20668829)
Clin Orthop Surg. 2010 Sep;2(3):130-9. (PMID: 20808583)
J Am Acad Orthop Surg. 2011 May;19(5):259-64. (PMID: 21536625)
Am J Sports Med. 2012 Mar;40(3):595-605. (PMID: 22184280)
Arthroscopy. 2012 Aug;28(8):1114-23. (PMID: 22421565)
BMC Musculoskelet Disord. 2012 Aug 27;13:161. (PMID: 22925587)
Clin Sports Med. 2013 Jan;32(1):155-64. (PMID: 23177469)
J Bone Joint Surg Am. 2013 Jan 16;95(2):103-8. (PMID: 23324957)
Am J Sports Med. 2013 Oct;41(10):2392-9. (PMID: 23893419)
Eklem Hastalik Cerrahisi. 2013;24(3):139-43. (PMID: 24191878)
Arthroscopy. 2014 May;30(5):593-8. (PMID: 24630956)
Am J Sports Med. 2014 Oct;42(10):2319-28. (PMID: 25201444)
Am J Sports Med. 2014 Oct;42(10):2301-10. (PMID: 25274353)
Clin J Sport Med. 2016 Mar;26(2):96-107. (PMID: 26164058)
BMC Musculoskelet Disord. 2015 Aug 19;16:200. (PMID: 26285568)
Knee Surg Sports Traumatol Arthrosc. 2017 Apr;25(4):1234-1240. (PMID: 26744280)
Am J Sports Med. 2016 Sep;44(9):2323-9. (PMID: 27365373)
Clin Orthop Relat Res. 2017 Oct;475(10):2459-2468. (PMID: 28205075)
Am J Sports Med. 2017 May;45(6):1326-1332. (PMID: 28273424)
Am J Sports Med. 2017 Jun;45(7):1567-1573. (PMID: 28298067)
Knee Surg Sports Traumatol Arthrosc. 2018 Feb;26(2):418-425. (PMID: 28324151)
Knee Surg Sports Traumatol Arthrosc. 2018 Feb;26(2):605-614. (PMID: 28477270)
BMC Musculoskelet Disord. 2018 Oct 12;19(1):368. (PMID: 30314478)
Arthroscopy. 1997 Jun;13(3):332-9. (PMID: 9195030)
فهرسة مساهمة: Keywords: ACL reconstruction; Press-fit fixation; Quadriceps tendon
تواريخ الأحداث: Date Created: 20190316 Date Completed: 20190712 Latest Revision: 20200225
رمز التحديث: 20221213
مُعرف محوري في PubMed: PMC6419498
DOI: 10.1186/s12891-019-2499-y
PMID: 30871508
قاعدة البيانات: MEDLINE