دورية أكاديمية

Patent ductus arteriosus stenting versus modified Blalock-Taussig shunt for palliation of duct-dependent pulmonary blood flow lesions.

التفاصيل البيبلوغرافية
العنوان: Patent ductus arteriosus stenting versus modified Blalock-Taussig shunt for palliation of duct-dependent pulmonary blood flow lesions.
المؤلفون: Helal AM; Paediatric Cardiology Division, Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia.; Paediatric Cardiology Division, Department of Paediatrics, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt., Elmahrouk AF; Cardiac Surgery Section, Department of Cardiovascular, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia.; Cardiothoracic Surgery Department, Faculty of Medicine Tanta University, Tanta, Egypt., Bekheet S; Paediatric Cardiology Division, Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia.; Paediatric Cardiology Division, Department of Paediatrics, Kasr Al Ainy School of Medicine, Cairo University, Cairo, Egypt., Barnawi HI; Cardiac Surgery Section, Department of Cardiovascular, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia., Jamjoom AA; Cardiac Surgery Section, Department of Cardiovascular, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia., Galal MO; Paediatric Cardiology Division, Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia., Abou Zahr R; Paediatric Cardiology Division, Department of Paediatrics, King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia.
المصدر: Journal of cardiac surgery [J Card Surg] 2022 Sep; Vol. 37 (9), pp. 2571-2580. Date of Electronic Publication: 2022 Jun 21.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Wiley-Blackwell Country of Publication: United States NLM ID: 8908809 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1540-8191 (Electronic) Linking ISSN: 08860440 NLM ISO Abbreviation: J Card Surg Subsets: MEDLINE
أسماء مطبوعة: Publication: Hoboken, NJ : Wiley-Blackwell
Original Publication: Mount Kisco, N.Y. : Futura Pub. Co., Inc., [c1986-
مواضيع طبية MeSH: Blalock-Taussig Procedure* , Ductus Arteriosus, Patent*/surgery, Cardiac Catheterization ; Humans ; Infant ; Palliative Care/methods ; Pulmonary Artery/surgery ; Pulmonary Circulation ; Retrospective Studies ; Stents ; Time Factors ; Treatment Outcome
مستخلص: Background: Patent ductus arteriosus (PDA) stenting is an alternative to modified Blalock-Taussig shunt (MBTS) as first-stage palliation of duct-dependent lesions. The superiority of one approach over the other is still controversial. Our objective was to compare PDA  stent versusMBTS for palliation in regard to safety, efficacy, and efficiency.
Methods: From 2010 to 2021, 134 patients had first-stage palliation with either PDA stent (n = 83) or MBTS (n = 51). Twenty-seven patients failed the primary treatment and were converted to the other group. The study endpoints were hospital outcomes, interstage reintervention, and concomitant procedures at the second-stage palliation.
Results: Patients with PDA stent were significantly younger. The prevalence of antegrade pulmonary blood flow (PBF) was higher in patients who had MBTS and graft thrombosis was higher in the PDA stent. Hospital stay was significantly longer in patients who had MBTS. Predictors of prolonged mechanical ventilation were low-weight, MBTS, and conversion. Intensive care unit stay significantly increased with conversion, low-weight, and antegrade PBF. The interstage intervention was required more frequently in PDA-stent group. Predictors of reintervention were conversion and pulmonary atresia with the intact interventricular septum. Pulmonary artery plasty was required more frequently during the second-stage palliation in PDA-stent group.
Conclusion: PDA stent is an alternative to MBTS for first-stage palliation. It is associated with shorter hospital stays and avoidance of surgery at the expense of a high rate of stent thrombosis and interstage reintervention. Conversion increased the risk of the procedure. More studies are needed to determine factors that affect PDA-stent outcomes and patient selection criteria.
(© 2022 Wiley Periodicals LLC.)
References: Dorobantu DM, Pandey R, Sharabiani MT, et al. Indications and results of systemic to pulmonary shunts: results from a national database. Eur J Cardio-Thoracic Surg. 2016;49(6):1553-1563.
Gibbs JL, Rothman MT, Rees MR, Parsons JM, Blackburn ME, Ruiz CE. Stenting of the arterial duct: a new approach to palliation for pulmonary atresia. Br Heart J. 1992;67(3):240-245.
Goldstein BH, O'Byrne ML, Petit CJ, et al. Differences in cost of care by palliation strategy for infants with ductal-dependent pulmonary blood flow. Circ Cardiovasc Interv. 2019;12(4):e007232.
Alwi M. Stenting the ductus arteriosus: case selection, technique and possible complications. Ann Pediatr Cardiol. 2008;1(1):38-45.
Hussain A, Al-Zharani S, Muhammed AA, Al-Ata J, Galal OM. Midterm outcome of stent dilatation of patent ductus arteriosus in ductal-dependent pulmonary circulation. Congenit Heart Dis. 2008;3(4):241-249. doi:10.1111/j.1747-0803.2008.00197.x.
Glatz AC, Petit CJ, Goldstein BH, et al. Comparison between patent ductus arteriosus stent and modified Blalock-Taussig shunt as palliation for infants with ductal-dependent pulmonary blood flow: insights from the Congenital Catheterization Research Collaborative. Circulation. 2018;137(6):589-601. doi:10.1161/CIRCULATIONAHA.117.029987.
Petrucci O, O'Brien SM, Jacobs ML, Jacobs JP, Manning PB, Eghtesady P. Risk factors for mortality and morbidity after the neonatal Blalock-Taussig shunt procedure. Ann Thorac Surg. 2011;92(2):642-652.
Boucek DM, Qureshi AM, Goldstein BH, Petit CJ, Glatz AC. Blalock-Taussig shunt versus patent ductus arteriosus stent as first palliation for ductal-dependent pulmonary circulation lesions: a review of the literature. Congenit Heart Dis. 2019;14(1):105-109.
Bentham JR, Zava NK, Harrison WJ, et al. Duct stenting versus modified Blalock-Taussig shunt in neonates with duct-dependent pulmonary blood flow: associations with clinical outcomes in a multicenter national study. Circulation. 2018;137(6):581-588.
Amoozgar H, Cheriki S, Borzoee M, et al. Short-term result of ductus arteriosus stent implantation compared with surgically created shunts. Pediatr Cardiol. 2012;33(8):1288-1294.
Mallula K, Vaughn G, El-Said H, Lamberti JJ, Moore JW. Comparison of ductal stenting versus surgical shunts for palliation of patients with pulmonary atresia and intact ventricular septum. Catheter Cardiovasc Interv. 2015;85(7):1196-1202.
Santoro G, Capozzi G, Caianiello G, et al. Pulmonary artery growth after palliation of congenital heart disease with duct-dependent pulmonary circulation: arterial duct stenting versus surgical shunt. J Am Coll Cardiol. 2009;54(23):2180-2186.
Santoro G, Gaio G, Capozzi G, et al. Fate of hypoplastic pulmonary arteries after arterial duct stenting in congenital heart disease with duct-dependent pulmonary circulation. JACC Cardiovasc Interv. 2015;8(12):1626-1632.
Vida VL, Speggiorin S, Maschietto N, et al. Cardiac operations after patent ductus arteriosus stenting in duct-dependent pulmonary circulation. Ann Thorac Surg. 2010;90(2):605-609.
McMullan DM, Permut LC, Jones TK, Johnston TA, Rubio AE. Modified Blalock-Taussig shunt versus ductal stenting for palliation of cardiac lesions with inadequate pulmonary blood flow. J Thorac Cardiovasc Surg. 2014;147(1):397-401.
فهرسة مساهمة: Keywords: PDA stenting; ductal-dependent pulmonary blood flow; modified Blalock-Taussig shunt
تواريخ الأحداث: Date Created: 20220621 Date Completed: 20220803 Latest Revision: 20220803
رمز التحديث: 20221213
DOI: 10.1111/jocs.16692
PMID: 35726659
قاعدة البيانات: MEDLINE
الوصف
تدمد:1540-8191
DOI:10.1111/jocs.16692