دورية أكاديمية

Calculation of the Biological Efficiency of the Proton Component from 14.8 MeV Neutron Irradiation in Computational Biology with Help of Video Cards.

التفاصيل البيبلوغرافية
العنوان: Calculation of the Biological Efficiency of the Proton Component from 14.8 MeV Neutron Irradiation in Computational Biology with Help of Video Cards.
المؤلفون: Gordon KB; Peoples' Friendship University of Russia (RUDN University), Moscow, Russia. gordon-kb@rudn.ru.; A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia. gordon-kb@rudn.ru., Saburov VO; A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia., Koryakin SN; A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia., Gulidov IA; A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia., Fatkhudinov TK; Peoples' Friendship University of Russia (RUDN University), Moscow, Russia., Arutyunyan IV; A. P. Avtsyn Research Institute of Human Morphology, Moscow, Russia., Kaprin AD; Peoples' Friendship University of Russia (RUDN University), Moscow, Russia., Solov'ev AN; A. F. Tsyb Medical Radiological Research Center, Affiliated Branch of the National Medical Research Radiological Center, Ministry of Health of the Russian Federation, Obninsk, Russia.
المصدر: Bulletin of experimental biology and medicine [Bull Exp Biol Med] 2022 Jun; Vol. 173 (2), pp. 281-285. Date of Electronic Publication: 2022 Jun 23.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Springer Country of Publication: United States NLM ID: 0372557 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1573-8221 (Electronic) Linking ISSN: 00074888 NLM ISO Abbreviation: Bull Exp Biol Med Subsets: MEDLINE
أسماء مطبوعة: Publication: New York : Springer
Original Publication: New York, Consultants Bureau.
مواضيع طبية MeSH: Proton Therapy*/methods , Protons*, Algorithms ; Computational Biology ; Neutrons
مستخلص: Fast neutron therapy, which previously has demonstrated effective results, but along with a large number of complications, can again be considered a promising treatment method in the treatment of cancer. One of the ways of analyzing the relative biological efficiency and accurate biological dose of fast neutrons in body tissues is to improve the algorithms of computational biology and mathematical modeling. A high-performance computing code was written which allows to estimate in real-time mode the biological dose of the proton component from the action of neutron radiation with an energy of 14.8 MeV. A comparative analysis of the computing performance on various video cards was also performed.
(© 2022. Springer Science+Business Media, LLC, part of Springer Nature.)
References: Gulidov IA, Aslanidi IP. On the state and prospects of development of remote neutron therapy. Vopr. Onkol. 2014;60(4):408-412. Russian. (PMID: 25552058)
Caswell RS, Coyne JJ. Interaction of neutrons and secondary charged particles with tissue: secondary particle spectra. Radiat. Res. 1972;52(3):448-470. (PMID: 10.2307/3573505)
Chatterjee A, Schaefer HJ. Microdosimetric structure of heavy ion tracks in tissue. Radiat. Environ. Biophys. 1976;13(3):215-227. doi: https://doi.org/10.1007/BF01330766. (PMID: 10.1007/BF01330766981514)
Cook S. CUDA Programming: A Developer’s Guide to Parallel Computing with GPUs. San Francisco, 2012.
Durante M. Proton beam therapy in Europe: more centres need more research. Br. J. Cancer. 2019;120(8):777-778. doi: https://doi.org/10.1038/s41416-018-0329-x. (PMID: 10.1038/s41416-018-0329-x30531831)
Frey K, Bauer J, Unholtz D, Kurz C, Krämer M, Bortfeld T, Parodi K. TPS(PET)-A TPS-based approach for in vivo dose verification with PET in proton therapy. Phys. Med. Biol. 2014;59(1):1-21. doi: https://doi.org/10.1088/0031-9155/59/1/1. (PMID: 10.1088/0031-9155/59/1/124323977)
Grzanka L, Greilich S, Korcyl M, Jäkel O, Waligórski M, Olko P. The application of amorphous track models to study cell survival in heavy ions beams. Radiat. Prot. Dosimetry. 2011;143(2-4):232-236. doi: https://doi.org/10.1093/rpd/ncq516. (PMID: 10.1093/rpd/ncq51621233095)
Jones B. Clinical Radiobiology of Fast Neutron Therapy: What Was Learnt? Front. Oncol. 2020;10:1537. doi: https://doi.org/10.3389/fonc.2020.01537. (PMID: 10.3389/fonc.2020.01537330427987522468)
Kiefer J, Straaten H. A model of ion track structure based on classical collision dynamics. Phys. Med. Biol. 1986;31(11):1201-1209. doi: https://doi.org/10.1088/0031-9155/31/11/002. (PMID: 10.1088/0031-9155/31/11/0023786407)
Manganaro L, Russo G, Bourhaleb F, Fausti F, Giordanengo S, Monaco V, Sacchi R, Vignati A, Cirio R, Attili A. ‘Survival’: a simulation toolkit introducing a modular approach for radiobiological evaluations in ion beam therapy. Phys. Med. Biol. 2018;63(8):08NT01. doi: https://doi.org/10.1088/1361-6560/aab697.
Mardynsky YS, Gulidov IA, Aminov GG, Ragulin YA, Kotuchov II, Gordon KB. Reactor neutrons in multimodality treatment of locally advanced breast carcinoma. Adv. Mater. Res. 2015;1084:464-466. doi: https://doi.org/10.4028/www.scientific.net/AMR.1084.464. (PMID: 10.4028/www.scientific.net/AMR.1084.464)
Mein S, Choi K, Kopp B, Tessonnier T, Bauer J, Ferrari A, Haberer T, Debus J, Abdollahi A, Mairani A. Fast robust dose calculation on GPU for high-precision 1H, 4He, 12C and 16O ion therapy: the FRoG platform. Sci Rep. 2018;8(1):14829. doi: https://doi.org/10.1038/s41598-018-33194-4. (PMID: 10.1038/s41598-018-33194-4302879306172246)
Qin N, Pinto M, Tian Z, Dedes G, Pompos A, Jiang SB, Parodi K, Jia X. Initial development of goCMC: a GPU-oriented fast cross-platform Monte Carlo engine for carbon ion therapy. Phys. Med. Biol. 2017;62(9):3682-3699. doi: https://doi.org/10.1088/1361-6560/aa5d43. (PMID: 10.1088/1361-6560/aa5d43281403525730973)
Schneider W, Bortfeld T, Schlegel W. Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. Phys. Med. Biol. 2000;45(2):459-478. doi: https://doi.org/10.1088/0031-9155/45/2/314. (PMID: 10.1088/0031-9155/45/2/31410701515)
Troshina MV, Koryakina EV, Potetnya VI, Koryakin SN, Pikalov VA, Antipov YuM. Induction of chromosome aberrations in B14-150 cells following carbon ions irradiation at low doses. J. Physics. Conf. Ser. 2020;1701:012029. doi https://doi.org/10.1088/1742-6596/1701/1/012029.
فهرسة مساهمة: Keywords: computational biology; fast neutron therapy; mathematical modeling; proton component; radiobiology
المشرفين على المادة: 0 (Protons)
تواريخ الأحداث: Date Created: 20220623 Date Completed: 20220630 Latest Revision: 20220630
رمز التحديث: 20231215
DOI: 10.1007/s10517-022-05534-y
PMID: 35737156
قاعدة البيانات: MEDLINE