Comparison of Continuous Real Time Blood Glucose Measurement With Venous Laboratory Blood Glucose Level in Neonates During Perioperative Period.
العنوان: | Comparison of Continuous Real Time Blood Glucose Measurement With Venous Laboratory Blood Glucose Level in Neonates During Perioperative Period. |
---|---|
المؤلفون: | Wasiq MA; Department of Pediatrics, KIMS Hospital, Bhubaneswar, Odisha., Behura SS; Department of Pediatrics, KIMS Hospital, Bhubaneswar, Odisha., Sahoo S; Department of Pediatrics, KIMS Hospital, Bhubaneswar, Odisha., Panda SK; Department of Pediatrics, KIMS Hospital, Bhubaneswar, Odisha. |
المصدر: | Indian pediatrics [Indian Pediatr] 2022 Aug 15; Vol. 59 (8), pp. 620-622. |
نوع المنشور: | Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Indian Pediatrics Country of Publication: India NLM ID: 2985062R Publication Model: Print Cited Medium: Internet ISSN: 0974-7559 (Electronic) Linking ISSN: 00196061 NLM ISO Abbreviation: Indian Pediatr Subsets: MEDLINE |
أسماء مطبوعة: | Publication: New Delhi : Indian Pediatrics Original Publication: Bombay. |
مواضيع طبية MeSH: | Blood Glucose*/analysis , Hyperglycemia*/diagnosis, Glucose ; Humans ; Infant, Newborn ; Perioperative Period ; Reproducibility of Results |
مستخلص: | Objectives: To compare the continuous real time blood glucose (CG) measurement with venous laboratory blood glucose (LG) level in neonates during perioperative period. Methods: Glucose levels were measured simultaneously by CG, glucometer glucose (GG) and LG at 40 time points in ten neonates during perioperative period. Intraclass correlation coefficient (ICC) and Bland Altman analysis were used for comparison. Result: Correlation between CG and LG was excellent (ICC= 0.953; P<0.001), and average difference was 23.8 (95%CI 52.9 to -5.3) mg/dL, showed better reliability than at hyperglycemic state (ICC=0.653; P=0.006). The GG-LG showed excellent reliability with ICC = 0.985; P<0.001 and average difference of 15.4 (95% CI 30.7 to 0.1) mg/dL. CG at euglycemic state (ICC= 0.880; P<0.001). Conclusion: CG measurement is reliable for blood sugar estimation in neonates; but has lower reliability for hyperglycemia. The continuous trend of glucose measurement by CG is helpful for timely diagnosis of hyperglycemia during perioperative period in neonates. |