دورية أكاديمية
3D printed opto-microfluidic autonomous analyzer for photometric applications.
العنوان: | 3D printed opto-microfluidic autonomous analyzer for photometric applications. |
---|---|
المؤلفون: | Rosa CE; National Technological Institute of Mexico - La Laguna, Mechanic and Mechatronics Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico.; Universidad de Guadalajara-CUCEI, Translational Biomedical Engineering Department, Av. Revolución #1500, Guadalajara, Jal, Mexico., Jorge FN; Universidad de Guadalajara-CUCEI, Translational Biomedical Engineering Department, Av. Revolución #1500, Guadalajara, Jal, Mexico., Luis GM; National Technological Institute of Mexico - La Laguna, Computer System Department, Revolución & Calz. Cuauhtemoc S/N Torreon, Coah., Mexico., Juana CE; National Technological Institute of Mexico - La Laguna, Electric and Electronic Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico., Edgar PD; National Technological Institute of Mexico - La Laguna, Mechanic and Mechatronics Department, Blvd. Revolución & Calz. Cuauhtemoc S/N, Torreon, Coah., Mexico. |
المصدر: | HardwareX [HardwareX] 2023 Feb 28; Vol. 14, pp. e00406. Date of Electronic Publication: 2023 Feb 28 (Print Publication: 2023). |
نوع المنشور: | Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Ltd Country of Publication: England NLM ID: 101710262 Publication Model: eCollection Cited Medium: Internet ISSN: 2468-0672 (Electronic) Linking ISSN: 24680672 NLM ISO Abbreviation: HardwareX Subsets: PubMed not MEDLINE |
أسماء مطبوعة: | Original Publication: [London] : Elsevier Ltd., [2017]- |
مستخلص: | 3D printed opto-microfluidic autonomous analyzer for photometric applications performs the automation of analytical micro-processes. The proposed device was designed under restrictions of small size and low energy consumption, which allow its portability for in-situ, on line and real time analysis. The autonomous process and auto-calibration consists of four functions: control and data acquisition; hydrodynamic: fluid pumping and flow injection; optical detection and wireless communication. All electronics systems where controlled with a virtual instrument interface. In the experiments carried out to measure fluorides, the results obtained were very close to those obtained with laboratory equipment. The consumption of reagents was 50% less and waste was reduced by 80%. The cost of the portable and autonomous microanalyzer is 75% less than large and robust laboratory equipment. Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (© 2023 The Author(s).) |
References: | Talanta. 2019 Aug 15;201:460-464. (PMID: 31122451) Anal Chim Acta. 2012 Feb 10;714:8-19. (PMID: 22244133) Anal Chem. 2002 Jun 15;74(12):2623-36. (PMID: 12090653) Talanta. 2018 Jun 1;183:201-208. (PMID: 29567165) Anal Chem. 1998 Dec 1;70(23):4974-84. (PMID: 21644679) Anal Chim Acta. 2020 Feb 8;1097:127-134. (PMID: 31910952) Anal Chim Acta. 2021 Mar 22;1151:338249. (PMID: 33608080) Anal Chim Acta. 2020 Oct 23;1135:187-203. (PMID: 33070854) Biotechnol J. 2020 May;15(5):e1900279. (PMID: 32045505) Sensors (Basel). 2011;11(5):5360-82. (PMID: 22163904) |
فهرسة مساهمة: | Keywords: Auto-calibration; Automation microprocesses; Hydrodynamic system; Microanalyzer; Optical detection; Opto-microfluidic |
تواريخ الأحداث: | Date Created: 20230313 Latest Revision: 20230314 |
رمز التحديث: | 20230314 |
مُعرف محوري في PubMed: | PMC9999204 |
DOI: | 10.1016/j.ohx.2023.e00406 |
PMID: | 36910021 |
قاعدة البيانات: | MEDLINE |
كن أول من يترك تعليقا!