Comparison of Cardiac Auscultation Features on Four Different Simulation Mannequins Performed by Pediatric Residents.

التفاصيل البيبلوغرافية
العنوان: Comparison of Cardiac Auscultation Features on Four Different Simulation Mannequins Performed by Pediatric Residents.
المؤلفون: Bahaidarah SA; Pediatrics, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU., Boker AM; Clinical Skills and Simulation Centre, Faculty of Medicine, King Abdulaziz University, Jeddah, SAU.
المصدر: Cureus [Cureus] 2023 Sep 12; Vol. 15 (9), pp. e45127. Date of Electronic Publication: 2023 Sep 12 (Print Publication: 2023).
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Cureus, Inc Country of Publication: United States NLM ID: 101596737 Publication Model: eCollection Cited Medium: Print ISSN: 2168-8184 (Print) Linking ISSN: 21688184 NLM ISO Abbreviation: Cureus Subsets: PubMed not MEDLINE
أسماء مطبوعة: Original Publication: Palo Alto, CA : Cureus, Inc.
مستخلص: Introduction: Cardiac murmurs are a common problem in pediatric clinical practice. Studies demonstrated low accuracy in detecting and diagnosing various cardiac murmurs at all levels of medical training. So, supplementary training methods started to evolve, including simulation for auscultation skills training. Over the years, mannequins have evolved with different types of technology. Therefore, we decided to compare cardiac auscultation accuracy among high-fidelity mannequins as the primary objective and compare the performance of various postgraduate-level residents as a secondary objective.
Method: Pediatric residents at King Abdulaziz University Hospital were given a lecture on the basics of cardiac auscultation and then requested to auscultate four mannequins, namely SimJumior® (Laerdal Medical, Stavanger, Norway), SimBaby™ (Laerdal Medical), Pediatric HAL® (Gaumard Scientific, Miami, FL, USA), and Cardiac Patient Simulator K-Plus (Kyoto Kagaku Co. Ltd., Kyoto, Japan). The accuracies of murmur type, diagnosis, and auscultation time were compared.  Results: A total of 56 pediatric residents were enrolled. Median murmur accuracy ranged from 50% to 53% (p-value 0.79), and median diagnosis accuracy ranged from 33% to 36% (p-value 0.77), with a nonsignificant difference between mannequins. Comparing resident levels in all mannequins, median murmur accuracy ranged from 49% to 56% (p-value 0.70), and median diagnosis accuracy ranged from 29% to 41% (p-value 0.09). While the median average auscultation time was between 41 and 50 seconds (p-value 0.34).
Conclusion: Auscultation skills can be taught through simulation on any mannequin used in this comparison, not necessarily the cardiac one. For better accuracy, future comparisons might include more advanced cardiac mannequins based on cardiac auscultation expertise (i.e., consultant level). The introduction of an auscultation program from the undergraduate level throughout the training process and monitoring of these skills are mandated.
Competing Interests: The authors have declared that no competing interests exist.
(Copyright © 2023, Bahaidarah et al.)
References: Pediatrics. 2000 Jun;105(6):1184-7. (PMID: 10835055)
J Contin Educ Health Prof. 2014 Spring;34(2):131-8. (PMID: 24939355)
Am J Med. 2001 Feb 15;110(3):210-6. (PMID: 11182108)
Ann Intern Med. 1993 Jul 1;119(1):47-54. (PMID: 8498764)
Med Educ. 2003 Nov;37 Suppl 1:22-8. (PMID: 14641635)
Arch Dis Child. 1999 Nov;81(5):409-12. (PMID: 10519714)
N Engl J Med. 1983 Jan 13;308(2):61-4. (PMID: 6847937)
J Gen Intern Med. 2010 Aug;25(8):780-5. (PMID: 20339952)
Intern Emerg Med. 2014 Mar;9(2):165-72. (PMID: 22767224)
Pediatrics. 2004 May;113(5):1331-5. (PMID: 15121949)
Med Educ. 2015 Mar;49(3):276-85. (PMID: 25693987)
Rev Esp Cardiol (Engl Ed). 2012 Dec;65(12):1135-6. (PMID: 22796032)
Acad Med. 1997 Oct;72(10 Suppl 1):S121-3. (PMID: 9347761)
J Contin Educ Health Prof. 2002 Summer;22(3):152-9. (PMID: 12227237)
Ann Card Anaesth. 2016 Jul-Sep;19(3):505-10. (PMID: 27397456)
J Gen Intern Med. 2001 Nov;16(11):763-9. (PMID: 11722691)
Arch Intern Med. 2006 Mar 27;166(6):610-6. (PMID: 16567598)
Qual Saf Health Care. 2004 Oct;13 Suppl 1:i11-8. (PMID: 15465949)
Med J Armed Forces India. 2012 Apr;68(2):167-72. (PMID: 24623932)
Chest. 2011 Feb;139(2):376-381. (PMID: 20829332)
Paediatr Anaesth. 2008 Jun;18(6):566-7. (PMID: 18445209)
Curr Opin Pediatr. 2009 Jun;21(3):282-7. (PMID: 19381090)
BMC Res Notes. 2015 Sep 10;8:427. (PMID: 26358413)
Clin Cardiol. 1990 Dec;13(12):869-72. (PMID: 2282731)
فهرسة مساهمة: Keywords: auscultation accuracy; auscultation skill; cardiac auscultation; cardiac mannequin; high fidelity mannequin
تواريخ الأحداث: Date Created: 20231016 Latest Revision: 20231020
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC10569741
DOI: 10.7759/cureus.45127
PMID: 37842489