دورية أكاديمية

Accuracy of models of partially edentulous arches obtained by three-dimensional printing: An in vitro study.

التفاصيل البيبلوغرافية
العنوان: Accuracy of models of partially edentulous arches obtained by three-dimensional printing: An in vitro study.
المؤلفون: Souza Curinga MR; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil., de Sousa LC; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil., Carneiro Pereira AL; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil., de Melo Segundo HV; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil., Cunha Maciel Dantas LM; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil., Carreiro ADFP; Department of Dentistry, Federal University of Rio Grande Do Norte (UFRN), Natal, Rio Grande Do Norte, Brazil.
المصدر: Journal of Indian Prosthodontic Society [J Indian Prosthodont Soc] 2023 Oct-Dec; Vol. 23 (4), pp. 356-362.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Medknow Publications Country of Publication: India NLM ID: 101255941 Publication Model: Print Cited Medium: Internet ISSN: 1998-4057 (Electronic) Linking ISSN: 09724052 NLM ISO Abbreviation: J Indian Prosthodont Soc Subsets: MEDLINE
أسماء مطبوعة: Publication: 2016- : Mumbai : Medknow Publications
Original Publication: 2001-2009: Mumbai : Medknow Publications
مواضيع طبية MeSH: Imaging, Three-Dimensional*/methods , Mouth, Edentulous*, Humans ; Models, Dental ; Printing, Three-Dimensional ; Incisor
مستخلص: Aim: The aim of this study was to evaluate the accuracy of models of partially edentulous arches obtained by three-dimensional (3D) printing.
Settings and Design: This was an in vitro study.
Materials and Methods: Fifteen partially edentulous models were evaluated, using two methods of measuring dimensions: virtual, using the Standard Tessellation Language files of the models and software (control group), and physical, through printing the models and digital caliper (test group). For both methods, measurements were made regarding the dimensions of the teeth (width and length - buccal/lingual or palatal/occlusal) and distances between the teeth.
Statistical Analysis Used: For the variable of linear measurements (width and length) and distances between teeth of the same hemiarch, the Wilcoxon test was used, while for the variable between opposite hemiarches, the paired t-test was used.
Results: In the evaluation of the linear measurements, a significant difference was observed only when the width of the molar tooth was analyzed (P = 0.014). When the buccal length was measured, all teeth had linear measurements provided by the virtual method that was lower than the physical (P = 0.000), as well as the lingual/palatal length in incisors (P = 0.003) and molars (P = 0.009) and in total (P = 0.001). As for the analyses between teeth, no difference was identified between the measurements provided by the virtual method compared to the physical one.
Conclusions: The 3D printer used to print partially edentulous models provided linear distortions in the teeth but without changes in the distances between teeth of the same hemiarch and between teeth of opposite hemiarches.
References: Int J Environ Res Public Health. 2020 Mar 18;17(6):. (PMID: 32197311)
J Prosthet Dent. 2018 Apr;119(4):586-592. (PMID: 28709674)
J Clin Med. 2020 May 12;9(5):. (PMID: 32408618)
Materials (Basel). 2022 Mar 24;15(7):. (PMID: 35407742)
Dent J (Basel). 2022 Sep 28;10(10):. (PMID: 36285991)
J Prosthet Dent. 2018 Apr;119(4):560-567.e1. (PMID: 28709680)
Stat Med. 2002 Jul 30;21(14):2109-29. (PMID: 12111890)
J Prosthet Dent. 2022 Nov;128(5):1041-1046. (PMID: 33785200)
Sensors (Basel). 2020 Feb 20;20(4):. (PMID: 32093174)
J Prosthet Dent. 2023 Jan 10;:. (PMID: 36635137)
Biometrics. 1977 Mar;33(1):159-74. (PMID: 843571)
J Prosthet Dent. 2021 Feb;125(2):241-248. (PMID: 32147252)
Scanning. 2021 Jul 17;2021:9950131. (PMID: 34367410)
Eur J Dent. 2020 Mar;14(2):189-193. (PMID: 32311750)
J Clin Epidemiol. 2008 Apr;61(4):344-9. (PMID: 18313558)
Polymers (Basel). 2022 Dec 13;14(24):. (PMID: 36559832)
J Dent. 2022 Sep;124:104212. (PMID: 35792192)
J Clin Med. 2020 Oct 20;9(10):. (PMID: 33092047)
فهرسة مساهمة: Keywords: Accuracy; dental arch; dental models; digital dentistry; partial-arch; three-dimensional printing
تواريخ الأحداث: Date Created: 20231020 Date Completed: 20231102 Latest Revision: 20231210
رمز التحديث: 20231215
مُعرف محوري في PubMed: PMC10705004
DOI: 10.4103/jips.jips_130_23
PMID: 37861612
قاعدة البيانات: MEDLINE
الوصف
تدمد:1998-4057
DOI:10.4103/jips.jips_130_23