دورية أكاديمية
Fat globule diameter in infant formulas.
العنوان: | Fat globule diameter in infant formulas. |
---|---|
المؤلفون: | Mendonça MA; Faculty of Agronomy and Veterinary Medicine, University of Brasília, Brasília, Campus Darcy Ribeiro, Asa Norte, Brasília, Brazil., Arruda SF; Department of Nutrition, College of Health Sciences, University of Brasília, Brasília, Campus Darcy Ribeiro, Asa Norte, Brasília, Brazil., de Alencar ER; Agricultural Engineering Department, Federal University of Viçosa (UFV), Viçosa, MG, Brazil., Araújo WMC; Department of Nutrition, College of Health Sciences, University of Brasília, Brasília, Campus Darcy Ribeiro, Asa Norte, Brasília, Brazil. Electronic address: wilma.araujo@terra.com.br. |
المصدر: | Nutrition (Burbank, Los Angeles County, Calif.) [Nutrition] 2024 May; Vol. 121, pp. 112264. Date of Electronic Publication: 2023 Oct 12. |
نوع المنشور: | Journal Article |
اللغة: | English |
بيانات الدورية: | Publisher: Elsevier Science Country of Publication: United States NLM ID: 8802712 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1873-1244 (Electronic) Linking ISSN: 08999007 NLM ISO Abbreviation: Nutrition Subsets: MEDLINE |
أسماء مطبوعة: | Publication: Tarrytown, NY : Elsevier Science Original Publication: [Burbank, Calif. : Nutrition, c1987- |
مواضيع طبية MeSH: | Infant Formula* , Milk, Human*/chemistry, Infant ; Humans ; Whey Proteins ; Fatty Acids/metabolism ; Glycoproteins |
مستخلص: | Objectives: The lipid fraction, fatty acid profile, and diameter of fat globules of infant formulas show great differences from human milk. These characteristics influence fat digestion and, consequently, the development and health of infants. The aim of this study was to evaluate the diameter of fat globules in infant formulas and compare them with those in human milk. Methods: The diameter of fat globules of 10 infant formulas and human milk samples was determined using scanning electron microscopy. Results: The starter infant formula was the only one that showed a mean diameter value (3.52 ± 2.17 µm) similar to that obtained for human milk (3.44 ± 1.68 µm). The starter infant formula showed the highest values of volume-surface D Conclusion: The analysis of principal components showed that none of the analyzed infant formulas had similarity with the diameter of fat globules and the fatty acid profile of human milk. Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. (Copyright © 2023. Published by Elsevier Inc.) |
فهرسة مساهمة: | Keywords: Diameter; Fat globules; Fatty acids; Human milk; Infant formula; Infants |
المشرفين على المادة: | 0 (Whey Proteins) 0 (Fatty Acids) 0 (Glycoproteins) |
تواريخ الأحداث: | Date Created: 20240308 Date Completed: 20240401 Latest Revision: 20240401 |
رمز التحديث: | 20240401 |
DOI: | 10.1016/j.nut.2023.112264 |
PMID: | 38458145 |
قاعدة البيانات: | MEDLINE |
تدمد: | 1873-1244 |
---|---|
DOI: | 10.1016/j.nut.2023.112264 |