دورية أكاديمية

Different methods of determining centric relation - comparison with a digital mandibular motion analyser.

التفاصيل البيبلوغرافية
العنوان: Different methods of determining centric relation - comparison with a digital mandibular motion analyser.
المؤلفون: Jász B; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary. jasz.balint@semmelweis.hu., Ambrus S; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary., Garay T; Faculty of Information Technology and Bionics, Pázmány Péter Catholic University, Budapest, Hungary.; Division of Oncology, Department of Internal Medicine and Oncology, Faculty of Medicine, Semmelweis University, Budapest, Hungary., Schmidt P; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary., Hermann P; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary., Körmendi S; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary., Jász M; Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Szentkirályi u. 47, Budapest, 1088, Hungary.
المصدر: BMC oral health [BMC Oral Health] 2024 Mar 18; Vol. 24 (1), pp. 345. Date of Electronic Publication: 2024 Mar 18.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: BioMed Central Country of Publication: England NLM ID: 101088684 Publication Model: Electronic Cited Medium: Internet ISSN: 1472-6831 (Electronic) Linking ISSN: 14726831 NLM ISO Abbreviation: BMC Oral Health Subsets: MEDLINE
أسماء مطبوعة: Original Publication: London : BioMed Central, [2001-
مواضيع طبية MeSH: Mandible* , Mandibular Condyle*, Male ; Female ; Humans ; Young Adult ; Adult ; Centric Relation ; Reproducibility of Results ; Chin ; Jaw Relation Record
مستخلص: Background: Finding and registering the maxillary-mandibular jaw relation is crucial in dental practice. Several comparative studies have been conducted to investigate the reproducibility and accuracy of techniques for determining the centric relation (CR) position of the mandible. The aim of our study was to determine which of seven different CR determination methods had the smallest deviation from the theoretical zero with the help of a digital mandibular motion analyser. The chosen theoretical zero position, the maximal intercuspal position (MIP), is the most reproducible and widely used position.
Methods: Thirty-four volunteers (24 females and 10 males) with a mean (SD) age of 29.1 (± 7.3) years with a negative history of temporomandibular disorder (TMD) participated in the study. A digital mandibular motion analyser was used to register the condylar position after the use of each technique for the determination of CR. The calibration was performed to the maximal intercuspal position (MIP) for each volunteer. The investigated techniques were (A) the gothic arch tracer, (B) the adduction field method, (C) Dawson's bimanual manipulation, (D) the patient placing the tongue tip on the palatal rugae, (E) the patient placing the tongue tip to the border of the hard and soft palate, (F) the patient actively pulling the chin backwards, and (G) the examiner pushing the patient's chin back.
Results: The position of the mandibular condyle was illustrated in a three-dimensional coordinate system, where the origin represented the MIP. Among the seven methods examined, five showed significant deviations compared to the MIP. Among these, two methods resulted in posterior deviation of the condyles. Methods C and E coincided with the MIP in all directions.
Conclusions: Within the limitations of our study, we found that the smallest deviations from our theoretical zero (MIP) among the investigated centric relation determining methods were obtained with the bimanual mandibular manipulation technique derived from Dawson and the placement of the tongue tip on the border of the hard and soft palate (linguomandibular homotrophy theory).
(© 2024. The Author(s).)
References: J Prosthodont. 2002 Mar;11(1):53-62. (PMID: 11935512)
J Prosthodont. 2023 Jul;32(6):497-504. (PMID: 36573906)
J Prosthet Dent. 2004 Mar;91(3):203-5. (PMID: 15060485)
J Prosthet Dent. 1977 Jul;38(1):66-109. (PMID: 328864)
J Prosthet Dent. 1987 Dec;58(6):713-62. (PMID: 3320355)
J Prosthet Dent. 1980 Mar;43(3):327-30. (PMID: 6928201)
Indian J Dent Res. 2012 Jan-Feb;23(1):122. (PMID: 22842268)
J Prosthet Dent. 1970 Jan;23(1):11-24. (PMID: 5261323)
J Am Dent Assoc. 1947 Aug 15;35(4):256-61. (PMID: 20255348)
J Biomech. 2020 Oct 9;111:109994. (PMID: 32971491)
J Prosthet Dent. 2017 Mar;117(3):426-429. (PMID: 27765398)
J Oral Rehabil. 2021 Sep;48(9):1050-1055. (PMID: 34164832)
J Prosthodont. 2003 Jun;12(2):90-101. (PMID: 12964681)
J Appl Oral Sci. 2009;17 Suppl:27-34. (PMID: 21499652)
J Am Dent Assoc. 1948 Nov;37(5):565-72. (PMID: 18888010)
J Prosthet Dent. 1973 Jan;29(1):100-12. (PMID: 4508618)
Int J Prosthodont. 2022 Dec 6;36(3):262–272. (PMID: 36484682)
Int J Oral Sci. 2016 Jun 30;8(2):126-32. (PMID: 27357324)
Quintessence Int. 2018;49(9):755-760. (PMID: 30202837)
J Prosthodont. 2021 Apr;30(S1):26-33. (PMID: 33783091)
Eur J Prosthodont Restor Dent. 2012 Dec;20(4):151-8. (PMID: 23495555)
J Prosthet Dent. 1997 Mar;77(3):280-4. (PMID: 9069083)
Am J Orthod Dentofacial Orthop. 2013 Oct;144(4):512-7. (PMID: 24075658)
J Prosthet Dent. 2005 Oct;94(4):389-93. (PMID: 16198178)
J Prosthet Dent. 2017 May;117(5S):e1-e105. (PMID: 28418832)
J Prosthet Dent. 2018 Jul;120(1):114-122. (PMID: 29526300)
J Prosthet Dent. 1996 Jan;75(1):60-6. (PMID: 8850454)
J Prosthet Dent. 1972 Dec;28(6):593-600. (PMID: 4508482)
فهرسة مساهمة: Keywords: Centric relation; Dawson’s method; Digital motion analysis; Gothic arch tracing
تواريخ الأحداث: Date Created: 20240319 Date Completed: 20240320 Latest Revision: 20240321
رمز التحديث: 20240321
مُعرف محوري في PubMed: PMC10946198
DOI: 10.1186/s12903-024-04131-x
PMID: 38500122
قاعدة البيانات: MEDLINE
الوصف
تدمد:1472-6831
DOI:10.1186/s12903-024-04131-x