دورية أكاديمية

Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry.

التفاصيل البيبلوغرافية
العنوان: Gafchromic EBT3 film provides equivalent dosimetric performance to EBT-XD film for stereotactic radiosurgery dosimetry.
المؤلفون: Smyth L; Australian Radiation Protection And Nuclear Safety Agency, Australian Clinical Dosimetry Service, Yallambie, VIC, Australia., Alves A; Australian Radiation Protection And Nuclear Safety Agency, Australian Clinical Dosimetry Service, Yallambie, VIC, Australia., Collins K; Australian Radiation Protection And Nuclear Safety Agency, Australian Clinical Dosimetry Service, Yallambie, VIC, Australia., Beveridge S; Australian Radiation Protection And Nuclear Safety Agency, Australian Clinical Dosimetry Service, Yallambie, VIC, Australia. sabeena.beveridge@arpansa.gov.au.
المصدر: Physical and engineering sciences in medicine [Phys Eng Sci Med] 2024 Sep; Vol. 47 (3), pp. 1095-1106. Date of Electronic Publication: 2024 May 13.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: Springer Country of Publication: Switzerland NLM ID: 101760671 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 2662-4737 (Electronic) Linking ISSN: 26624729 NLM ISO Abbreviation: Phys Eng Sci Med Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Switzerland : Springer, [2020]-
مواضيع طبية MeSH: Film Dosimetry* , Radiosurgery* , Phantoms, Imaging*, Humans ; Calibration
مستخلص: The accurate assessment of film results is highly dependent on the methodology and techniques used to process film. This study aims to compare the performance of EBT3 and EBT-XD film for SRS dosimetry using two different film processing methods. Experiments were performed in a solid water slab and an anthropomorphic head phantom. For each experiment, the net optical density of the film was calculated using two different methods; taking the background (initial) optical density from 1) an unirradiated film from the same film lot as the irradiated film (stock to stock (S-S) method), and 2) a scan of the same piece of film taken prior to irradiation (film to film (F-F) method). EBT3 and EBT-XD performed similarly across the suite of experiments when using the green channel only or with triple channel RGB dosimetry. The dosimetric performance of EBT-XD was improved across all colour channels by using an F-F method, particularly for the blue channel. In contrast, EBT3 performed similarly well regardless of the net optical density method used. Across 21 SRS treatment plans, the average per-pixel agreement between EBT3 and EBT-XD films, normalised to the 20 Gy prescription dose, was within 2% and 4% for the non-target (2-10 Gy) and target (> 10 Gy) regions, respectively, when using the F-F method. At doses relevant to SRS, EBT3 provides comparable dosimetric performance to EBT-XD. In addition, an S-S dosimetry method is suitable for EBT3 while an F-F method should be adopted if using EBT-XD.
(© 2024. Crown.)
References: Med Phys. 2015 Oct;42(10):5782-6. (PMID: 26429252)
J Natl Compr Canc Netw. 2017 Dec;15(12):1494-1502. (PMID: 29223987)
J Appl Clin Med Phys. 2016 Sep 08;17(5):466-481. (PMID: 27685125)
J Appl Clin Med Phys. 2016 Nov 08;17(6):312-322. (PMID: 27929504)
Phys Med Biol. 2018 Mar 15;63(6):065007. (PMID: 29474189)
Phys Eng Sci Med. 2022 Mar;45(1):251-259. (PMID: 35113342)
Phys Med. 2021 Feb;82:150-157. (PMID: 33618154)
J Appl Clin Med Phys. 2015 Mar 08;16(2):5141. (PMID: 26103181)
Phys Imaging Radiat Oncol. 2021 Oct 19;20:40-45. (PMID: 34722939)
Phys Med Biol. 2015 Nov 21;60(22):8741-52. (PMID: 26512917)
Med Phys. 2020 Dec;47(12):5986-6025. (PMID: 32990328)
فهرسة مساهمة: Keywords: Audit; Dosimetry; EBT-XD; EBT3; Film; Radiochromic film; Stereotactic radiosurgery
تواريخ الأحداث: Date Created: 20240513 Date Completed: 20240917 Latest Revision: 20240920
رمز التحديث: 20240920
مُعرف محوري في PubMed: PMC11408406
DOI: 10.1007/s13246-024-01430-z
PMID: 38739345
قاعدة البيانات: MEDLINE
الوصف
تدمد:2662-4737
DOI:10.1007/s13246-024-01430-z