دورية أكاديمية
Comprehensive imaging evaluation of the aortic valve and root before aortic root surgery: a study comparing MDCT and TEE.
العنوان: | Comprehensive imaging evaluation of the aortic valve and root before aortic root surgery: a study comparing MDCT and TEE. |
---|---|
المؤلفون: | Li Y; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Diseases, No. 167 North Lishi Road, Xicheng District, Beijing, 100037, China., Zhang S; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Diseases, No. 167 North Lishi Road, Xicheng District, Beijing, 100037, China., Qi H; Department of Ultrasound, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Disease, Beijing, China., Ma X; Department of Radiology, Fuwai Hospittal, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Diseases, Beijing, China., Qian X; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Diseases, No. 167 North Lishi Road, Xicheng District, Beijing, 100037, China. m13701097213@163.com., Sun J; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College/National Center for Cardiovascular Diseases, No. 167 North Lishi Road, Xicheng District, Beijing, 100037, China. sunsanjing@126.com. |
المصدر: | BMC cardiovascular disorders [BMC Cardiovasc Disord] 2024 Jul 16; Vol. 24 (1), pp. 367. Date of Electronic Publication: 2024 Jul 16. |
نوع المنشور: | Journal Article; Comparative Study |
اللغة: | English |
بيانات الدورية: | Publisher: BioMed Central Country of Publication: England NLM ID: 100968539 Publication Model: Electronic Cited Medium: Internet ISSN: 1471-2261 (Electronic) Linking ISSN: 14712261 NLM ISO Abbreviation: BMC Cardiovasc Disord Subsets: MEDLINE |
أسماء مطبوعة: | Original Publication: London : BioMed Central, [2001- |
مواضيع طبية MeSH: | Aortic Valve*/diagnostic imaging , Aortic Valve*/surgery , Aortic Valve*/abnormalities , Predictive Value of Tests* , Multidetector Computed Tomography* , Echocardiography, Transesophageal* , Bicuspid Aortic Valve Disease*/surgery , Bicuspid Aortic Valve Disease*/diagnostic imaging, Humans ; Male ; Female ; Middle Aged ; Aged ; Reproducibility of Results ; Adult ; Retrospective Studies ; Heart Valve Diseases/diagnostic imaging ; Heart Valve Diseases/surgery ; Preoperative Care |
مستخلص: | Objective: To investigate the accuracy and consistency of MDCT and TEE in the preoperative assessment of aortic root surgery. Methods: From January 2021 to September 2022, 118 patients who underwent aortic root surgery were included in this study. All patients underwent high-quality preoperative MDCT and TEE examinations, and the examination results were independently measured and assessed by two senior radiologists or ultrasound specialists. Bland-Altman analysis and Pearson correlation testing were employed to assess the correlation and consistency between MDCT and TEE. These analyses were then compared with actual intraoperative measurement data. Results: Among all the patients, 73 (61.86%) had tricuspid aortic valve (TAV), and 45 (38.14%) had bicuspid aortic valve (BAV). A comparison between the TEE and MDCT measurements showed that for the annulus diameter, the area-derived diameter had the best correlation and agreement. For the sinus of Valsalva diameter, the circumference-derived diameter was optimal. However, for the STJ diameter, the minimum cross-sectional diameter showed the best agreement with TEE. In contrast, measurements of geometric height showed a weaker correlation and agreement. Conclusion: Contrast-enhanced MDCT can be a valuable tool for perioperative evaluation in aortic root surgery, with good correlation, consistency, and feasibility when compared to TEE. The choice of MDCT measurement methodology, specifically area-derived and circumference-derived diameter, proved to be more accurate than other methods. Further research is required to enhance the understanding of aortic valve repair and associated imaging techniques. (© 2024. The Author(s).) |
References: | J Thorac Cardiovasc Surg. 2014 Sep;148(3):872-9; discussion 879-80. (PMID: 24930611) Ann Thorac Surg. 2004 Oct;78(4):1479-81. (PMID: 15464530) J Thorac Cardiovasc Surg. 1993 Mar;105(3):435-8. (PMID: 8445922) Int J Cardiol. 2019 Feb 1;276:230-235. (PMID: 30213599) Am J Cardiol. 2006 Oct 1;98(7):966-9. (PMID: 16996884) J Thorac Cardiovasc Surg. 2006 Aug;132(2):436-8. (PMID: 16872982) J Am Soc Echocardiogr. 2020 Jun;33(6):692-734. (PMID: 32503709) Eur J Cardiothorac Surg. 2006 Apr;29(4):537-44. (PMID: 16500110) J Thorac Cardiovasc Surg. 2003 Apr;125(4):773-8. (PMID: 12698136) Eur J Cardiothorac Surg. 2022 Jul 11;62(2):. (PMID: 35583290) J Cardiovasc Thorac Res. 2021;13(3):208-215. (PMID: 34630968) J Thorac Cardiovasc Surg. 1995 Feb;109(2):345-51; discussion 351-2. (PMID: 7853886) Circulation. 2022 Dec 13;146(24):e334-e482. (PMID: 36322642) Eur J Cardiothorac Surg. 2018 May 1;53(5):1040-1048. (PMID: 29253123) Front Cardiovasc Med. 2021 Nov 22;8:731440. (PMID: 34881298) Eur J Echocardiogr. 2010 Sep;11(8):645-58. (PMID: 20823280) Semin Thorac Cardiovasc Surg. 1993 Jan;5(1):88-90. (PMID: 8425009) Ann Thorac Surg. 2023 Apr;115(4):879-885. (PMID: 36370884) |
معلومات مُعتمدة: | No. Z201100005520003 Beijing Municipal Science & Technology Commission; No. Z201100005520003 Beijing Municipal Science & Technology Commission; No. Z201100005520003 Beijing Municipal Science & Technology Commission |
فهرسة مساهمة: | Keywords: Aortic root surgery; Multidetector coomputed tomography; Transeophageal echocardiography |
تواريخ الأحداث: | Date Created: 20240716 Date Completed: 20240716 Latest Revision: 20240719 |
رمز التحديث: | 20240719 |
مُعرف محوري في PubMed: | PMC11251224 |
DOI: | 10.1186/s12872-024-04031-6 |
PMID: | 39014301 |
قاعدة البيانات: | MEDLINE |
تدمد: | 1471-2261 |
---|---|
DOI: | 10.1186/s12872-024-04031-6 |