دورية أكاديمية

Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits.

التفاصيل البيبلوغرافية
العنوان: Center of Pressure Measurement Accuracy via Insoles with a Reduced Pressure Sensor Number during Gaits.
المؤلفون: Fuchs PX; Department of Athletic Performance, National Taiwan Normal University, No. 88, Section 4, Tingzhou Road, Wenshan District, Taipei City 116, Taiwan.; Department of Physical Education and Sport Sciences, National Taiwan Normal University, No. 162, Section 1, Heping East Road, Da'an District, Taipei City 106, Taiwan., Chen WH; Department of Athletic Performance, National Taiwan Normal University, No. 88, Section 4, Tingzhou Road, Wenshan District, Taipei City 116, Taiwan.; Department of Physical Education and Kinesiology, National Dong Hwa University, No. 1, Section 2, Da Hsueh Road, Shoufeng District, Hualian City 974301, Taiwan., Shiang TY; Department of Athletic Performance, National Taiwan Normal University, No. 88, Section 4, Tingzhou Road, Wenshan District, Taipei City 116, Taiwan.
المصدر: Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Jul 29; Vol. 24 (15). Date of Electronic Publication: 2024 Jul 29.
نوع المنشور: Journal Article
اللغة: English
بيانات الدورية: Publisher: MDPI Country of Publication: Switzerland NLM ID: 101204366 Publication Model: Electronic Cited Medium: Internet ISSN: 1424-8220 (Electronic) Linking ISSN: 14248220 NLM ISO Abbreviation: Sensors (Basel) Subsets: MEDLINE
أسماء مطبوعة: Original Publication: Basel, Switzerland : MDPI, c2000-
مواضيع طبية MeSH: Pressure* , Gait*/physiology , Walking*/physiology , Shoes*, Humans ; Male ; Female ; Adult ; Running/physiology ; Young Adult ; Foot Orthoses ; Jogging/physiology ; Biomechanical Phenomena
مستخلص: The objective was to compare simplified pressure insoles integrating different sensor numbers and to identify a promising range of sensor numbers for accurate center of pressure (CoP) measurement. Twelve participants wore a 99-sensor Pedar-X insole (100 Hz) during walking, jogging, and running. Eight simplified layouts were simulated, integrating 3-17 sensors. Concordance correlation coefficients (CCC) and root mean square errors (RMSE) between the original and simplified layouts were calculated for time-series mediolateral (ML) and anteroposterior (AP) CoP. Differences between layouts and between gait types were assessed via ANOVA and Friedman test. Concordance between the original and simplified layouts varied across layouts and gaits (CCC: 0.43-0.98; χ(7)2 ≥ 34.94, p < 0.001). RMSE ML and RMSE AP [mm], respectively, were smaller in jogging (5 ± 2, 15 ± 9) than in walking (8 ± 2, 22 ± 4) and running (7 ± 4, 20 ± 7) (ηp2: 0.70-0.83, p < 0.05). Only layouts with 11+ sensors achieved CCC ≥ 0.80 in all tests across gaits. The 13-sensor layout achieved CCC ≥ 0.95 with 95% confidence, representing the most promising compromise between sensor number and CoP accuracy. Future research may refine sensor placement, suggesting the use of 11-13 sensors. For coaches, therapists, and applied sports scientists, caution is recommended when using insoles with nine or fewer sensors. Consulting task-specific validation results for the intended products is advisable.
References: J Biomech. 2005 Sep;38(9):1881-5. (PMID: 16023476)
Sensors (Basel). 2021 Feb 19;21(4):. (PMID: 33669674)
J Sports Sci. 2017 May;35(10):953-959. (PMID: 27400240)
Gait Posture. 2016 May;46:69-74. (PMID: 27131180)
Sensors (Basel). 2020 Jan 24;20(3):. (PMID: 31991637)
Neurophysiol Clin. 2015 Nov;45(4-5):285-95. (PMID: 26388359)
Gait Posture. 2006 Feb;23(2):189-99. (PMID: 16399515)
Gait Posture. 2016 Feb;44:29-36. (PMID: 27004629)
Med Eng Phys. 2011 Jun;33(5):638-45. (PMID: 21310644)
J Sports Sci. 2017 Jan;35(2):196-206. (PMID: 27010531)
J Biomech. 2008 Aug 7;41(11):2597-601. (PMID: 18571656)
Wounds. 2007 Dec;19(12):350-62. (PMID: 25942685)
Med Eng Phys. 2016 Dec;38(12):1489-1494. (PMID: 27745875)
Foot Ankle. 1987 Apr;7(5):262-76. (PMID: 3583160)
IEEE Trans Biomed Eng. 2013 Dec;60(12):3284-90. (PMID: 23475336)
J Manipulative Physiol Ther. 2014 Nov-Dec;37(9):696-701. (PMID: 25267441)
PLoS One. 2017 Jun 9;12(6):e0175724. (PMID: 28599003)
Med Biol Eng Comput. 2017 Apr;55(4):537-548. (PMID: 27311606)
Sensors (Basel). 2018 Apr 21;18(4):. (PMID: 29690496)
Sensors (Basel). 2012;12(7):9884-912. (PMID: 23012576)
Sports Biomech. 2022 May 2;:1-14. (PMID: 35499556)
Sensors (Basel). 2018 Oct 25;18(11):. (PMID: 30366375)
Psychol Bull. 1992 Jul;112(1):155-9. (PMID: 19565683)
فهرسة مساهمة: Keywords: analysis; assessment; biomechanics; kinetics; technology
تواريخ الأحداث: Date Created: 20240810 Date Completed: 20240810 Latest Revision: 20240812
رمز التحديث: 20240813
مُعرف محوري في PubMed: PMC11315048
DOI: 10.3390/s24154918
PMID: 39123967
قاعدة البيانات: MEDLINE
الوصف
تدمد:1424-8220
DOI:10.3390/s24154918