دورية أكاديمية

[ROC analysis of image quality in digital luminescence radiography in comparison with current film-screen systems in mammography].

التفاصيل البيبلوغرافية
العنوان: [ROC analysis of image quality in digital luminescence radiography in comparison with current film-screen systems in mammography].
عنوان ترانسليتريتد: ROC-Analyse zur Bildqualität der digitalen Lumineszenzradiographie im Vergleich zu herkömmlichen Film-Folien-Systemen auf dem Gebiet der Mammographie.
المؤلفون: Wiebringhaus R; Zentralinstitut für Röntgendiagnostik, Universitätsklinikum Essen., John V, Müller RD, Hirche H, Voss M, Callies R
المصدر: Aktuelle Radiologie [Aktuelle Radiol] 1995 Jul; Vol. 5 (4), pp. 263-7.
نوع المنشور: Comparative Study; Journal Article
اللغة: German
بيانات الدورية: Publisher: Georg Thieme Verlag Country of Publication: Germany NLM ID: 9102962 Publication Model: Print Cited Medium: Print ISSN: 0939-267X (Print) Linking ISSN: 0939267X NLM ISO Abbreviation: Aktuelle Radiol Subsets: MEDLINE
أسماء مطبوعة: Publication: Stuttgart : Georg Thieme Verlag
Original Publication: Stuttgart ; New York : Georg Thieme Verlag, c1991-
مواضيع طبية MeSH: X-Ray Intensifying Screens*, Breast Neoplasms/*diagnostic imaging , Mammography/*instrumentation , Radiographic Image Enhancement/*instrumentation , Radiographic Magnification/*instrumentation , Xeromammography/*instrumentation, Calcinosis/diagnostic imaging ; Female ; Humans ; Mammography/statistics & numerical data ; Models, Anatomic ; ROC Curve ; Xeromammography/statistics & numerical data
مستخلص: Aim: To compare in mammography the image quality of digital luminescence radiography (DLR) to that of usual film screen mammography and xeromammography.
Materials and Methods: Three single emulsion film-screen combinations, one double coated high resolution film and xeroradiography, were tested for this purpose. In our phantom study the detectability of microcalcifications, fibrils and low contrast details were first of all studied separately. Image processing techniques were, for example, contrast variation by grey scale level windowing, "unsharp mask" filtering and regulatable edge enhancement. Phantom images were made and then the image quality was evaluated by observer performance study using a receiver operating characteristic (ROC analysis).
Results: Best results in respect of detection of microcalcifications and fibrils were found in xeroradiography, luminescent image plate and double-coated film-screen combination. These systems showed more favourable ROC curves than the single emulsion film-screen combinations.
Conclusions: Our results indicate that image quality of digital images in the field of image processing is equal to that of conventional mammographic techniques and partially superior to detection of low contrast details.
تواريخ الأحداث: Date Created: 19950701 Date Completed: 19951102 Latest Revision: 20161123
رمز التحديث: 20240829
PMID: 7548257
قاعدة البيانات: MEDLINE