مستخلص: The naphthalene sublimation technique via the heat and mass transfer analogy is used to study the effects of the pitch of in-line delta winglet vortex generators on heat transfer and pressure drop of a finned three-row flat tube bank. The results show that the pitch of the in-line vortex generator has a strong effect on the heat transfer performance. The optimal pitch depends on the performance evaluation criteria. With the configurations considered in this article, for identical pumping power or combined constraint, a small pitch of 0.33 is best; for the identical pressure drop constraint, a value of 0.42 is best. [ABSTRACT FROM AUTHOR]
Copyright of Experimental Heat Transfer is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)