دورية أكاديمية

Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation.

التفاصيل البيبلوغرافية
العنوان: Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation.
المؤلفون: HIROSHI SATAKE, NAOMI HANAKA, RYUSUKE HONMA, TADAYOSHI WATANABE, SHIGERU INOUE, YUMIKO KANAUCHI, YOSHIHIRO KATO, TAKU NAKAJIMA, DAISUKE SATO, JUN ETO, MASAHIRO MARUYAMA, YASUSHI NAGANUMA, JUNYA SASAKI, SHUJI TOYONO, MIKIO HARADA, DAISUKE ISHIGAKI, MASATOSHI TAKAHARA, MICHIAKI TAKAGI, Satake, Hiroshi, Hanaka, Naomi
المصدر: Orthopedics; Sep/Oct2016, Vol. 39 Issue 5, pe893-e896, 4p
مصطلحات موضوعية: CARPAL tunnel syndrome, COMPARATIVE studies, FRACTURE fixation, BONE fractures, RANGE of motion of joints, LONGITUDINAL method, RESEARCH methodology, MEDICAL cooperation, PERIPHERAL neuropathy, ORTHOPEDIC implants, RADIUS bone injuries, RESEARCH, ORGAN rupture, SURGICAL complications, TENDON injuries, WRIST, EVALUATION research, DISEASE incidence, RETROSPECTIVE studies
مستخلص: The current study investigated the incidence of complications after surgery for distal radial fractures. This multicenter retrospective study was conducted at 11 institutions. A total of 824 patients who had distal radius fractures that were treated surgically between January 2010 and August 2012 were identified. The study patients were older than 18 years and were observed for at least 12 weeks after surgery for distal radius fractures with a volar locking plate. Sex, age, fracture type according to AO classification, implants, wrist range of motion, grip strength, fracture consolidation rate, and complications were studied. Analysis included 694 patients, including 529 women and 165 men, with a mean age of 64 years. The mean follow-up period was 27 weeks. The fracture consolidation rate was 100%. There were 52 complications (7.5%), including 18 cases of carpal tunnel syndrome, 12 cases of peripheral nerve palsy, 8 cases of trigger digit, 4 cases of tendon rupture (none of the flexor pollicis longus), and 10 others. There was no rupture of the flexor pollicis longus tendon because careful attention was paid to the relationship between the implant and the tendon. Peripheral nerve palsy may have been caused by intraoperative traction in 7 cases, temporary fixation by percutaneous Kirschner wires in 3 cases, and axillary nerve block in 1 case; 1 case appeared to be idiopathic. Tendon ruptures were mainly caused by mechanical stress. [Orthopedics.2016; 39(5):e893-e896.]. [ABSTRACT FROM AUTHOR]
Copyright of Orthopedics is the property of SLACK Incorporated and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:01477447
DOI:10.3928/01477447-20160517-05