دورية أكاديمية

Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea.

التفاصيل البيبلوغرافية
العنوان: Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea.
المؤلفون: Vázquez, J C, Tsai, W H, Flemons, W W, Masuda, A, Brant, R, Hajduk, E, Whitelaw, W A, Remmers, J E
المصدر: Thorax; Apr2000, p302-307, 6p
مصطلحات موضوعية: ALGORITHMS, CLINICAL trials, COMPARATIVE studies, LONGITUDINAL method, RESEARCH methodology, MEDICAL cooperation, OXIMETRY, QUESTIONNAIRES, RESEARCH, SLEEP apnea syndromes, POLYSOMNOGRAPHY, EVALUATION research, RANDOMIZED controlled trials
مستخلص: Background: The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG.Methods: Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal.Results: The PSG derived apnoea hypopnea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15. 62)/h and the sensitivity and specificity profile did not change significantly.Conclusions: In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA. [ABSTRACT FROM AUTHOR]
Copyright of Thorax is the property of BMJ Publishing Group and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index