مستخلص: Background and Aims: Acute lower gastrointestinal bleeding (LGIB) is a common cause of emergency hospitalization and may require readmission for re-bleeding. Recently, a novel endoscopic hemostatic powder (UI-EWD/Nexpowder™, Nextbiomedical, Incheon, South Korea) was developed and applied for the control of LGIB. The aim of this study was to evaluate the hemostatic efficacy and long-term safety of UI-EWD in LGIB.Patients and Methods: We conducted a retrospective cohort study of LGIB at a single tertiary center in south Korea. One hundred and sixty-seven consecutive patients with LGIB who were initially successful in endoscopic hemostasis were included and divided into the conventional treatment group (n = 112) and the UI-EWD therapy group (n = 55; 38 patients with conventional treatment and 17 patients with UI-EWD alone). The success rate of hemostasis, adverse events related to UI-EWD, and re-bleeding rate were evaluated.Results: The incidence of endoscopic hemostasis applied to the hepatic flexure (7.3% vs. 0%, p = 0.011) and larger than 4 cm (25.5% vs. 8.0%, p = 0.002) were significantly higher in the UI-EWD group than in the conventional therapy group. The cumulative rebleeding rate within 28 days in the UI-EWD group was 5.5% (3/55), which was significantly lower than that in the conventional treatment group (17.0% [19/112]; p = 0.039). No UI-EWD-related adverse events were recorded.Conclusion: Based on our results, application of UI-EWD in LGIB showed promising results for the prevention of re-bleeding, especially in locations where it is difficult to approach or cases with more bleeding. There were no significant complications, such as perforation or embolism. In particular, UI-EWD should be considered first for anatomical or technical impediments to endoscopic access in LGIB. [ABSTRACT FROM AUTHOR]
Copyright of BMC Gastroenterology is the property of BioMed Central and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:1471230X
DOI:10.1186/s12876-022-02247-4