Rounded Biphasic Waveform Reduces Energy Requirements for Transvenous Catheter Cardioversion of Atrial Fibrillation and Flutter.

التفاصيل البيبلوغرافية
العنوان: Rounded Biphasic Waveform Reduces Energy Requirements for Transvenous Catheter Cardioversion of Atrial Fibrillation and Flutter.
المؤلفون: Harbinson, M. T., Allen, J. D., Imam, Zafar, Dempsey, G., McC Anderson, J., Ayers, G. M., Adgey, A. Aj.
المصدر: Pacing & Clinical Electrophysiology; Jan1997, Vol. 20 Issue 1, p226-229, 4p
مصطلحات موضوعية: ATRIAL fibrillation, CATHETERIZATION, MEDICAL equipment, HEART diseases, CARDIOLOGY, CARDIAC patients
مستخلص: We postulated that reducing peak leading edge shock voltage and its rate of rise (waveform rounding) would reduce energy requirements for cardioversion of AF and AFl, and may therefore reduce patient discomfort. Transvenous defibrillating catheters (In-Control Inc.) were placed in the RAA (active fixation) and the CS of six anesthetized sheep. AF or AFl was induced by electrical stimulation (100 Hz, 2 V; Grass stimulator). A standard trapezoidal biphasic (S) waveform (3-ms duration each phase) was compared with a similar waveform that had the first phase rounded (H). Cardioversion was attempted after 30 seconds of arrhythmia, using a Ventritex HVS-O2 defibrillator modified to allow waveform rounding. Each waveform was randomly tested several times at 100-, 150-. and 200-V leading edges, and percentage cardioversion success calculated. Shock energy was calculated from delivered current and voltage using Flukeview (Fluke, Inc.) software. At 100-V leading edge R (64% success) and S (59%), shocks were similarly efficacious (P = 0.37). However. R delivered less current, voltage, and energy than the comparable S shock (means 1.30 A, 65.0 V, 0.33 f B vs 1.92 A, 94.2 V, 0.47 JS;P = 0.0001). Both waveforms were equally successful at 150 V (88% vs 100%; P = NS) and 200 V (100% vs 100%), but again R delivered less current, voltage, and energy (2.05 A, 102.5 V, 0.82 J R vs 2.78 A, 142.3 V. 1.11 f S at 150 V: 2.76 A, 141.2 V, 1.56 J R vs 3.77 A, 189.4 V. 2.03 J S at 200 V; both P = 0.0001). No arrhythmic or other complications occurred in the 174 shocks delivered. Waveform rounding reduces delivered peak voltage, current, and energy without reducing defibrillation efficacy. To determine if these changes are associated with a reduction in discomfort, patients with AF are currently being cardioverted with these waveforms during electrophysiological studies. [ABSTRACT FROM AUTHOR]
Copyright of Pacing & Clinical Electrophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index