دورية أكاديمية

Assessment of current methane emission quantification techniques for natural gas midstream applications.

التفاصيل البيبلوغرافية
العنوان: Assessment of current methane emission quantification techniques for natural gas midstream applications.
المؤلفون: Liu, Yunsong, Paris, Jean-Daniel, Broquet, Gregoire, Bescós Roy, Violeta, Meixus Fernandez, Tania, Andersen, Rasmus, Russu Berlanga, Andrés, Christensen, Emil, Courtois, Yann, Dominok, Sebastian, Dussenne, Corentin, Eckert, Travis, Finlayson, Andrew, Fernández de la Fuente, Aurora, Gunn, Catlin, Hashmonay, Ram, Grigoleto Hayashi, Juliano, Helmore, Jonathan, Honsel, Soeren, Innocenti, Fabrizio
المصدر: Atmospheric Measurement Techniques; 2024, Vol. 17 Issue 6, p1633-1649, 17p
مصطلحات موضوعية: NATURAL gas, WIND speed, GAS compressors, METHANE, WEATHER
مستخلص: Methane emissions from natural gas systems are increasingly scrutinized, and accurate reporting requires quantification of site- and source-level measurement. We evaluate the performance of 10 available state-of-the-art CH 4 emission quantification approaches against a blind controlled-release experiment at an inerted natural gas compressor station in 2021. The experiment consisted of 17 blind 2 h releases at a single exhaust point or multiple simultaneous ones. The controlled releases covered a range of methane flow rates from 0.01 to 50 kg h -1. Measurement platforms included aircraft, drones, trucks, vans, ground-based stations, and handheld systems. Herewith, we compare their respective strengths, weaknesses, and potential complementarity depending on the emission rates and atmospheric conditions. Most systems were able to quantify the releases within an order of magnitude. The level of errors from the different systems was not significantly influenced by release rates larger than 0.1 kg h -1 , with much poorer results for the 0.01 kg h -1 release. It was found that handheld optical gas imaging (OGI) cameras underestimated the emissions. In contrast, the "site-level" systems, relying on atmospheric dispersion, tended to overestimate the emission rates. We assess the dependence of emission quantification performance on key parameters such as wind speed, deployment constraints, and measurement duration. At the low wind speeds encountered (below 2 m s -1), the experiments did not reveal a significant dependence on wind speed. The ability to quantify individual sources degraded during multiple-source releases. Compliance with the Oil and Gas Methane Partnership's (OGMP 2.0) highest level of reporting may require a combination of the specific advantages of each measurement technique and will depend on reconciliation approaches. Self-reported uncertainties were either not available or were based on the standard deviation in a series of independent realizations or fixed values from expert judgment or theoretical considerations. For most systems, the overall relative errors estimated in this study are higher than self-reported uncertainties. [ABSTRACT FROM AUTHOR]
Copyright of Atmospheric Measurement Techniques is the property of Copernicus Gesellschaft mbH and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:18671381
DOI:10.5194/amt-17-1633-2024