دورية أكاديمية

A two-miRNA signature (miR-21 and miR-92) in peripheral whole blood as a potential biomarker for diagnosis of human cerebral aneurysms.

التفاصيل البيبلوغرافية
العنوان: A two-miRNA signature (miR-21 and miR-92) in peripheral whole blood as a potential biomarker for diagnosis of human cerebral aneurysms.
المؤلفون: Congying Zheng, Chengliang Mao, Kai Tang, Shaojian Ceng, Hang Shu
المصدر: Archives of Medical Science; Jun2024, Vol. 20 Issue 3, p726-735, 10p
مصطلحات موضوعية: INTRACRANIAL aneurysms, MICRORNA, GENE expression, BIOMARKERS, RECEIVER operating characteristic curves
مستخلص: Introduction: microRNAs (miRs) have been reported as blood-based noninvasive indicators for the diagnosis of various diseases. However, the utility of whole blood-based miRs in the diagnosis of intracranial aneurysm (IA) is still not clear. The present study aimed to examine miR expression profiling in the peripheral whole blood of IA patients and healthy controls. Material and methods: Seventy-three IA patients, including 34 unruptured and 39 ruptured, and 28 healthy subjects, were recruited for diagnostic analysis. microRNA (miR) expression profiling in whole blood from healthy controls and IA patients was evaluated using miRNA microarray assay. RT-qPCR was used to evaluate miR expression. Receiver operating characteristics (ROC) curves and the area under the ROC curves (AUC) were used to calculate the diagnostic power of miRs in whole blood of IA. Results: We observed significantly higher miR-21 and miR-92 expression levels in aneurysmal tissues and whole blood of IA patients as compared to healthy subjects. miR-21 expression level was significantly positively correlated with miR-92 in IA tissues and whole blood of IA patients. ROC analysis revealed that miR-21 (AUC = 0.843, sensitivity = 0.849, specificity = 0.750) and miR-92 (AUC = 0.892, sensitivity = 0.945, specificity = 0.786) were promising in diagnosis of IA with high detectability. Intriguingly, miR-21 combined with miR-92 markedly improved the diagnostic power of IA (AUC = 0.920, sensitivity = 1.000, specificity = 0.786). Conclusions: miR-21 combined with miR-92 could be considered as a potential biomarker for IA screening. [ABSTRACT FROM AUTHOR]
Copyright of Archives of Medical Science is the property of Termedia Publishing House and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:17341922
DOI:10.5114/aoms.2020.93536