دورية أكاديمية

Determinazione dell'etanolo con metodo enzimatico su matrici diverse.

التفاصيل البيبلوغرافية
العنوان: Determinazione dell'etanolo con metodo enzimatico su matrici diverse. (Italian)
Alternate Title: Determination of ethanol using an enzymatic method in different matrices. (English)
المؤلفون: Galla, Luisa, Marchioro, Lucio, Marinova, Mariela, Artusi, Carlo, Zaninotto, Martina, Basso, Daniela, Plebani, Mario
المصدر: Biochimica Clinica; Jun2024, Vol. 48 Issue 2, p142-147, 6p
مصطلحات موضوعية: BLOOD alcohol, ETHANOL, BLOOD sampling
People: LI He
مستخلص: Introduction: this study was designed to measure ethyl alcohol concentrations in blood samples of different matrices (Li-He plasma, K2-EDTA plasma and serum) with the DRI® method on the ILab Taurus analyzer. The aim of the protocol was to compare the values between the matrices K2-EDTA and serum with Li-He plasma. Furthermore, 18 real samples from the emergency room were used to compare the results obtained with the enzymatic method on both Li-He and K2-EDTA plasma in comparison with the GC/HS reference method. Methods: serum, Li-He and K2-EDTA samples were obtained from left-over routine samples to obtain different pools (serum, Li-He plasma and K2-EDTA plasma pools). Samples with different expected concentrations of ethanol (range 0.00-2.22 g/L) were prepared in situ (60 samples for each matrix) by precise additions of a 10% ethanol solution. All these samples were stored at -20°C until use. Results: in the expected concentration range between 0.42 and 0.85 g/L and around 0.8 and 1.5 g/L [which incorporates most of the legally permitted levels of BAC (Blood Alcohol Concentration) in Europe including Italy] the CV% obtained are all <5.0%. The GC/HS correlation with ILab Taurus for both plasma matrices, LI-He and K2-EDTA evaluated in 18 genuine samples was excellent. Discussion: all the obtained results show that for all the matrices evaluated in the study, the analytical performances are highly satisfactory. [ABSTRACT FROM AUTHOR]
Copyright of Biochimica Clinica is the property of SIBioC - Laboratory Medicine and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:03930564
DOI:10.19186/BC_2023.095