دورية أكاديمية

Experimental and Numerical Study of Newly Assembled Lightweight Radiant Floor Heating System.

التفاصيل البيبلوغرافية
العنوان: Experimental and Numerical Study of Newly Assembled Lightweight Radiant Floor Heating System.
المؤلفون: Zhang, Baogang, Wang, Yongjuan, Liu, Ming, Zhang, Zhongbing
المصدر: Buildings (2075-5309); Jul2024, Vol. 14 Issue 7, p2096, 25p
مصطلحات موضوعية: HEAT capacity, RADIANT heating, WATER supply, WASTE recycling, WATER temperature, HEATING
مستخلص: In this study, the heating capacity of a new prefabricated assembled hot water radiant modular heating system made from a recycled waste building masonry structure is investigated through experimental and numerical simulation methods. The heating capacity of the system in different working conditions (a water supply temperature of 48 °C, 51 °C, 56 °C, and 61 °C; a flow rate of 0.49 m3/h, 0.35 m3/h, and 0.21 m3/h) is analyzed and verified. A three-dimensional steady-state heat transfer numerical model of the floor heat transfer of the module is established, and the accuracy of the model is verified through the measured results to investigate the heating capacity of this system under different water supply temperatures, flow rates and coil spacings. The results show that the new prefabricated hot water radiant module heating system has a 0.9 °C higher air temperature and 2.1 °C higher average floor surface temperature than the traditional wet floor radiant heating system under the same experimental conditions, and the response time is 44% shorter. The water supply temperature can significantly change the heating capacity of the system, while the water supply flow rate has little effect on the system. The established three-dimensional steady-state numerical model can be in good agreement with the measured results. This study can provide an experimental and theoretical basis for the design and application of such systems. [ABSTRACT FROM AUTHOR]
Copyright of Buildings (2075-5309) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20755309
DOI:10.3390/buildings14072096