دورية أكاديمية

Test–retest reliability of lower limb muscle strength, jump and sprint performance tests in elite female team handball players.

التفاصيل البيبلوغرافية
العنوان: Test–retest reliability of lower limb muscle strength, jump and sprint performance tests in elite female team handball players.
المؤلفون: Fristrup, Bjørn, Krustrup, Peter, Kristensen, Kevin Højer, Rasmussen, Steffen, Aagaard, Per
المصدر: European Journal of Applied Physiology; Sep2024, Vol. 124 Issue 9, p2577-2589, 13p
مصطلحات موضوعية: VERTICAL jump, CENTER of mass, MUSCLE strength, WOMEN athletes, HANDBALL players, PHOTOELECTRIC cells
مستخلص: Purpose: This study aimed to assess the reliability of lower limb muscle function (knee extensor/flexor peak torque, rate of torque development (RTD), impulse, and countermovement jump (CMJ) performance) and sprint performance (acceleration capacity). Methods: CMJ performance was evaluated on a force plate. MVIC, RTD and impulse variables were investigated using a portable isometric dynamometer and sprint performance was assessed with dual-beam photocells in elite female athletes. Results: CMJ test variables maximal vertical jump height, peak and mean power, concentric work, and body center of mass displacement demonstrated good-to-excellent test–retest correlations between Test 1 and Test 2 (ICC ≥ 0.70, CWw-s = 3.4–11.0%). Peak MVIC torque for the knee extensors and flexors demonstrated excellent test–retest correlations (both ICC = 0.84) along with CVw-s values of 6.8 and 6.0%, respectively. Late-phase (0–100 ms, 0–200 ms) RTD for the knee flexors demonstrated excellent test–retest correlations (ICC = 0.89–0.91, CVw-s = 4.8–8.5%). Sprint times at 10- and 20-m demonstrated excellent test–retest reproducibility (ICC = 0.83 and ICC = 0.90, respectively) with CVw-s values of 1.9 and 1.5%. For 5-m sprint times, test–retest reproducibility was good (ICC = 0.71) with CVw-s of 2.8%. Sprint testing performed while dribbling a handball improved (p < 0.05) from test to retest at 5-, 10- and 20-m. Conclusion: In conclusion, the force plate, the mobile isometric dynamometer, and dual-beam photocells provide reproducible tools for field-based testing of countermovement jump performance, knee extensor and flexor strength and sprint performance. [ABSTRACT FROM AUTHOR]
Copyright of European Journal of Applied Physiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:14396319
DOI:10.1007/s00421-024-05470-x