دورية أكاديمية

Microbubble-Size Dependence of Focused Ultrasound-Induced Blood-B rain Barrier Opening in Mice In Vivo.

التفاصيل البيبلوغرافية
العنوان: Microbubble-Size Dependence of Focused Ultrasound-Induced Blood-B rain Barrier Opening in Mice In Vivo.
المؤلفون: Choi, James J., Feshitan, Jameel A., Baseri, Babak, Shougang Wang, Yao-Sheng Tung, Borden, Mark A., Konofagou, Elisa E.
المصدر: IEEE Transactions on Biomedical Engineering; Jan2010, Vol. 57 Issue 1, p145-154, 10p
مصطلحات موضوعية: BLOOD-brain barrier, SONICATION, MICROBUBBLE diagnosis, DEXTRAN, CENTRIFUGATION, FLUORESCENCE
مستخلص: The therapeutic efficacy of neurological agents is severely limited, because large compounds do not cross the blood- brain barrier (BBB). Focused ultrasound (FUS) sonication in the presence of microbubbles has been shown to temporarily open the BBB, allowing systemically administered agents into the brain. Until now, polydispersed microbubbles (1-10 μm in diameter) were used, and, therefore, the bubble sizes better suited for inducing the opening remain unknown. Here, the FUS-induced BBB opening dependence on microbubble size is investigated. Bubbles at 1-2 and 4-5 μm in diameter were separately size-isolated using differential centrifugation before being systemically administered in mice (n = 28). The BBB opening pressure threshold was identified by varying the peak-rarefactional pressure amplitude. BBB opening was determined by fluorescence enhancement due to systemically administered, fluorescent-tagged, 3-kDa dextran. The identified threshold fell between 0.30 and 0.46 MPa in the case of 1-2 ,μm bubbles and between 0.15 and 0.30 MPa in the 4-5 μm case. At every pressure studied, the fluorescence was greater with the 4-5 μm than with the 1-2 μm bubbles. At 0.61 MPa, in the 1-2 μm bubble case, the fluorescence amount and area were greater in the thalamus than in the hippocampus. In conclusion, it was determined that the FUS-induced BBB opening was dependent on both the size distribution in the injected microbubble volume and the brain region targeted. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Biomedical Engineering is the property of IEEE and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index