The Use of Aptamers and Molecularly Imprinted Polymers in Biosensors for Environmental Monitoring: A Tale of Two Receptors

التفاصيل البيبلوغرافية
العنوان: The Use of Aptamers and Molecularly Imprinted Polymers in Biosensors for Environmental Monitoring: A Tale of Two Receptors
المؤلفون: Jon Ashley, Mohsen Mohammadniaei, Maryam Naseri, Yi Sun
المصدر: Chemosensors, Vol 8, Iss 32, p 32 (2020)
Naseri, M, Mohammadniaei, M, Sun, Y & Ashley, J 2020, ' The use of aptamers and molecularly imprinted polymers in biosensors for environmental monitoring: A tale of two receptors ', Chemosensors, vol. 8, no. 2, 32 . https://doi.org/10.3390/CHEMOSENSORS8020032
بيانات النشر: MDPI AG, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Aptamer, Computer science, 02 engineering and technology, 01 natural sciences, antibiotics, Analytical Chemistry, lcsh:Biochemistry, Environmental monitoring, lcsh:QD415-436, Physical and Theoretical Chemistry, 010401 analytical chemistry, Molecularly imprinted polymer, aptamer, pathogens, Heavy metals, heavy metal, 021001 nanoscience & nanotechnology, 0104 chemical sciences, Heavy metal, Molecularly imprinted polymers, environmental contaminants, Antibiotics Elfamycin Genome sequence Kirromycin Streptomycetes, molecularly imprinted polymers, Biochemical engineering, Pathogens, 0210 nano-technology, Biosensor, Environmental contaminants
الوصف: Effective molecular recognition remains a major challenge in the development of robust receptors for biosensing applications. Over the last three decades, aptamers and molecularly imprinted polymers (MIPs) have emerged as the receptors of choice for use in biosensors as viable alternatives to natural antibodies, due to their superior stability, comparable binding performance, and lower costs. Although both of these technologies have been developed in parallel, they both suffer from their own unique problems. In this review, we will compare and contrast both types of receptor, with a focus on the area of environmental monitoring. Firstly, we will discuss the strategies and challenges involved in their development. We will also discuss the challenges that are involved in interfacing them with the biosensors. We will then compare and contrast their performance with a focus on their use in the detection of environmental contaminants, namely, antibiotics, pesticides, heavy metals, and pathogens detection. Finally, we will discuss the future direction of these two technologies.
وصف الملف: application/pdf
تدمد: 2227-9040
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5c321186cdbb51988422f4880fe3350b
https://doi.org/10.3390/chemosensors8020032
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....5c321186cdbb51988422f4880fe3350b
قاعدة البيانات: OpenAIRE