A randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer

التفاصيل البيبلوغرافية
العنوان: A randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer
المؤلفون: Yundai Chen, Lian Chen, Zhi-jun Sun, Qinhua Jin, Hong-bin Liu, Chang-fu Liu, Feng Tian, Luyue Gai, Jun Guo
المصدر: Molecular Medicine Reports. 7:1191-1196
بيانات النشر: Spandidos Publications, 2013.
سنة النشر: 2013
مصطلحات موضوعية: Male, Cancer Research, Pathology, medicine.medical_specialty, Intimal hyperplasia, Polymers, medicine.medical_treatment, Biodegradable Plastics, Biochemistry, Optical coherence tomography, Genetics, medicine, Humans, Stent implantation, Molecular Biology, Aged, Sirolimus, chemistry.chemical_classification, medicine.diagnostic_test, business.industry, Coronary Stenosis, Stent, Drug-Eluting Stents, Polymer, Middle Aged, medicine.disease, Biodegradable polymer, Treatment Outcome, Oncology, chemistry, Molecular Medicine, Female, Open label, Tunica Intima, business, Nuclear medicine, Tomography, Optical Coherence, medicine.drug
الوصف: Intimal hyperplasia appears to differ after implanting a drug-eluting stent (DES) with a biodegradable or a permanent polymer. The aim of the present study was to compare biodegradable with permanent polymer DES, since the available data are limited. One hundred patients with de novo coronary artery stenosis were included in this study. The patients were classified into 2 groups: DES with a biodegradable polymer (n=50) and DES with a permanent polymer (n=50). Optical coherence tomography (OCT) examination was performed before and after stent implantation. A follow‑up OCT, performed 1 year after stent implantation, compared the morphologies of intimal hyperplasia in the 2 groups. The frequencies of uncovered stent struts (2.27 vs. 1.87%, P=0.145) and stent strut malapposition (1.9 vs. 2.02%, P=0.655) upon the first-year follow-up were not significantly different. Average neointimal thickness was lower in the biodegradable compared with the permanent polymer group (106.12±80.65 vs. 181.20±146.96 µm, P
تدمد: 1791-3004
1791-2997
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5f39b7af7ec766cb82836be93ceea8ab
https://doi.org/10.3892/mmr.2013.1313
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....5f39b7af7ec766cb82836be93ceea8ab
قاعدة البيانات: OpenAIRE