Spectral Characteristics of the Double-Folded Slot Antennas with Cold-Electron Bolometers for the 220/240 GHz Channels of the LSPE Instrument
العنوان: | Spectral Characteristics of the Double-Folded Slot Antennas with Cold-Electron Bolometers for the 220/240 GHz Channels of the LSPE Instrument |
---|---|
المؤلفون: | V. O. Zbrozhek, Silvia Masi, Paolo de Bernardis, L. S. Revin, Anna V. Gordeeva, Anton V. Blagodatkin, Andrey L. Pankratov, I. V. Rakut, A. V. Chiginev, Dmitry A. Pimanov, Leonid Kuzmin |
المصدر: | Applied Sciences Volume 11 Issue 22 Applied Sciences, Vol 11, Iss 10746, p 10746 (2021) |
بيانات النشر: | Multidisciplinary Digital Publishing Institute, 2021. |
سنة النشر: | 2021 |
مصطلحات موضوعية: | Cryostat, Josephson effect, Technology, coplanar line, Materials science, QH301-705.5, QC1-999, double-folded slot antenna, Slot antenna, YBaCuO, law.invention, Optics, law, Josephson junction, General Materials Science, cold-electron bolometer, Biology (General), Cold-electron bolometer, Coplanar line, Double-folded slot antenna, Resonant properties, QD1-999, Instrumentation, Fluid Flow and Transfer Processes, business.industry, Physics, Process Chemistry and Technology, Bandwidth (signal processing), Bolometer, General Engineering, Resonance, Engineering (General). Civil engineering (General), Line (electrical engineering), Computer Science Applications, Chemistry, TA1-2040, business, Noise (radio), resonant properties |
الوصف: | We present the results of the experimental and theoretical study of the resonant properties and noise of a single cell of a receiving system based on cold-electron bolometers (CEB) with a double-folded slot antenna and coplanar lines. The system was designed to receive signals at 220/240 GHz frequencies with a 5% bandwidth. In measurements, we used the samples of the double-folded slot antennas with slot lengths of 162 um and coplanar line lengths from 185 to 360 um. Measurements of the resonance properties of CEB located at 0.3 K cryostat plate were carried out using a generator based on a high-temperature YBCO Josephson junction located inside the same cryostat at 4 K plate. This arrangement made it possible to obtain smooth amplitude-frequency characteristics with a clearly defined peak of a 15–21 GHz bandwidth at different frequencies. Based on these results, 2-D array of double-folded slot antennas with CEBs as 220/240 GHz LSPE channel prototype was calculated.The absorption efficiency of the array has reached 81% and 77% for 220 and 240 GHz channels, respectively. |
وصف الملف: | application/pdf |
اللغة: | English |
تدمد: | 2076-3417 |
DOI: | 10.3390/app112210746 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::735ae2ec5b0aae8f480be71f1260861a |
حقوق: | OPEN |
رقم الأكسشن: | edsair.doi.dedup.....735ae2ec5b0aae8f480be71f1260861a |
قاعدة البيانات: | OpenAIRE |
تدمد: | 20763417 |
---|---|
DOI: | 10.3390/app112210746 |