Levosimendan Versus Intra-aortic Balloon Pump in High-Risk Cardiac Surgery Patients

التفاصيل البيبلوغرافية
العنوان: Levosimendan Versus Intra-aortic Balloon Pump in High-Risk Cardiac Surgery Patients
المؤلفون: Patrizia Caravetta, Lucio Di Pirro, Angela Lappa, A. Menichetti, Luca Severi, Sacha Jerome Luzzi, Giovanni Landoni, Pierluigi Cipullo
المساهمون: Severi, L, Lappa, A, Landoni, Giovanni, Di Pirro, L, Luzzi, Sj, Caravetta, P, Cipullo, P, Menichetti, A.
سنة النشر: 2011
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, medicine.medical_treatment, law.invention, Risk Factors, law, Intensive care, Internal medicine, medicine, Humans, Cardiac Surgical Procedures, Coronary Artery Bypass, Hospitals, Teaching, Simendan, Aged, Intra-aortic balloon pump, Mechanical ventilation, Intra-Aortic Balloon Pumping, business.industry, Hydrazones, Levosimendan, Perioperative, Length of Stay, Middle Aged, medicine.disease, Intensive care unit, Cardiac surgery, Pyridazines, Anesthesiology and Pain Medicine, Heart failure, Cardiology, Mitral Valve, Female, Cardiology and Cardiovascular Medicine, business, medicine.drug
الوصف: Objective: Patients with severe left ventricular dysfunction receive inotropic and mechanical circulatory support with an intra-aortic balloon pump (IABP) during the perioperative phase of cardiac surgery. The authors performed the first comparison of levosimendan versus an IABP in patients with poor left ventricular function undergoing cardiac surgery. Design: A case-matched study. Setting: A teaching hospital. Participants: Twenty-two heart failure patients scheduled to undergo elective coronary artery bypass graft surgery with or without concomitant mitral surgery. Interventions: Eleven patients received levosimendan at a dose of 0.1 mu g/kg/min for 24 hours without an initial bolus. The control group, also 11 patients, received a preoperative IABP. The intensive care unit stay was the major endpoint of this study. Biochemical, hemodynamic, and echocardiographic data were collected together with the time on mechanical ventilation and 30-day mortality. Measurements and Main Results: The length of intensive care unit stay was reduced in patients receiving levosimendan (median, 2.5; range, 1-3 days) compared with those receiving an IABP (median, 5; range, 3-6 days; p = 0.01). No deaths occurred in the levosimendan group; 1 patient died in the intra-aortic balloon pump group. Conclusions: Patients receiving levosimendan had a shorter duration of intensive care stay than peers who received a preoperative IABP. The findings of this pilot study should be investigated further in a large randomized controlled study. (C) 2011 Elsevier Inc. All rights reserved.
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::84050479dda96de9d26f57b02edfdb4a
حقوق: OPEN
رقم الأكسشن: edsair.doi.dedup.....84050479dda96de9d26f57b02edfdb4a
قاعدة البيانات: OpenAIRE