Influence of the integrity of tendinous membrane and fascicle on biomechanical characteristics of tendon-derived scaffolds

التفاصيل البيبلوغرافية
العنوان: Influence of the integrity of tendinous membrane and fascicle on biomechanical characteristics of tendon-derived scaffolds
المؤلفون: Zhong Zhang, Tingwu Qin, Yan-Jing Zhang, Wei Ding, Shu-Kun He, Jingcong Luo, Jing Cui, Xuan Yao, Liang-Ju Ning, Yi Zhang
المصدر: Biomedical materials (Bristol, England). 16(1)
سنة النشر: 2020
مصطلحات موضوعية: Materials science, 0206 medical engineering, Biomedical Engineering, Bioengineering, Strain (injury), Biocompatible Materials, 02 engineering and technology, In Vitro Techniques, Biomaterials, Tendons, Weight-Bearing, Suture (anatomy), Tensile Strength, Ultimate tensile strength, Materials Testing, medicine, Animals, Tendon healing, Decellularization, Sutures, Tissue Scaffolds, Biomechanics, Fascicle, Plastic Surgery Procedures, 021001 nanoscience & nanotechnology, medicine.disease, 020601 biomedical engineering, Tendon, Biomechanical Phenomena, medicine.anatomical_structure, Microscopy, Electron, Scanning, Cattle, 0210 nano-technology, Biomedical engineering
الوصف: The biomechanical characteristics of tendon grafts is essential for tendon reconstructive surgery due to its great role in providing a good mechanical environment for tendon healing and regeneration. In our previous studies, the decellularized tendon slices (DTSs) and decellularized bovine tendon sheets (DBTSs) scaffolds were successfully developed. However, the influence of the integrity of tendinous membrane (endotenon and epitenon) and fascicle on biomechanical characteristics of these two scaffolds was not investigated. In this study, we assessed the integrity of tendinous membrane and fascicle of the tendon derived scaffolds and its effect on the biomechanical characteristics. The results of histological staining indicated that the DBTSs had complete endotenon and epitenon, while DTSs had no epitenon at all, only part of endotenon was remained. Furthermore, the DBTSs, and DTSs with thickness of 900 μm had complete fascicles, while DTSs with thickness less than 600 μm had almost no complete fascicles. The fibrous configuration of epitenon was well-preserved in the surface of the DBTSs but the surface ultrastructure of the DTSs was aligned collagen fibers based on scanning electron microscopy examination. The results of transmission electron microscopy showed that there was no significant difference between the DBTSs and DTSs. Mechanically, the DBTSs and DTSs with thickness of 900 μm showed similar ultimate tensile strength and stiffness to native tendon segments (NTSs). The strain at break and suture retention strength of the DBTSs showed much higher than that of the DTSs (p < 0.05). Additionally, the DBTSs showed higher ultimate load than the DTSs when these scaffolds were sutured with NTSs (p < 0.05) through the modified Kessler technique based on a uniaxial tensile test. This study demonstrated that DTSs may be used as a patch for reinforcing tendon repair, while DBTSs may be used as a bridge for reconstructing tendon defects.
تدمد: 1748-605X
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::eac76737e5c343fd4bf45a6b7eab1657
https://pubmed.ncbi.nlm.nih.gov/33065568
حقوق: CLOSED
رقم الأكسشن: edsair.doi.dedup.....eac76737e5c343fd4bf45a6b7eab1657
قاعدة البيانات: OpenAIRE