Neutron collimator design of neutron radiography based on the BNCT facility

التفاصيل البيبلوغرافية
العنوان: Neutron collimator design of neutron radiography based on the BNCT facility
المؤلفون: Yang, XP., Yu, BX., Li, YG., Peng, D., Lu, J., Zhang, GL., Zhao, H., Zhang, AW., Li, CY., Liu, WJ., Hu, T., Lv, JG.
سنة النشر: 2013
المجموعة: Nuclear Experiment
Physics (Other)
مصطلحات موضوعية: Physics - Instrumentation and Detectors, Nuclear Experiment
الوصف: For the research of CCD neutron radiography, a neutron collimator was designed based on the exit of thermal neutron of the Boron Neutron Capture Therapy (BNCT) reactor. Based on the Geant4 simulations, the preliminary choice of the size of the collimator was determined. The materials were selected according to the literature data. Then, a collimator was constructed and tested on site. The results of experiment and simulation show that the thermal neutron flux at the end of theneutron collimator is greater than 10^6 n/cm^2/s, the maximum collimation ratio (L/D) is 58, the Cd-ratio(Mn) is 160 and the diameter of collimator end is 10 cm. This neutron collimator is considered to be applicable for neutron radiography.
Comment: 5 pages, 5 figures, 6 references
نوع الوثيقة: Working Paper
DOI: 10.1088/1674-1137/38/2/028201
URL الوصول: http://arxiv.org/abs/1305.0672
رقم الأكسشن: edsarx.1305.0672
قاعدة البيانات: arXiv
الوصف
DOI:10.1088/1674-1137/38/2/028201