Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment

التفاصيل البيبلوغرافية
العنوان: Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment
المؤلفون: Arenz, M., Baek, W. -J., Beck, M., Beglarian, A., Behrens, J., Bergmann, T., Berlev, A., Besserer, U., Blaum, K., Bode, T., Bornschein, B., Bornschein, L., Brunst, T., Buzinsky, N., Chilingaryan, S., Choi, W. Q., Deffert, M., Doe, P. J., Dragoun, O., Drexlin, G., Dyba, S., Edzards, F., Eitel, K., Ellinger, E., Engel, R., Enomoto, S., Erhard, M., Eversheim, D., Fedkevych, M., Fischer, S., Formaggio, J. A., Fränkle, F. M., Franklin, G. B., Friedel, F., Fulst, A., Gil, W., Glück, F., Ureña, A. Gonzalez, Grohmann, S., Grössle, R., Gumbsheimer, R., Hackenjos, M., Hannen, V., Harms, F., Haußmann, N., Heizmann, F., Helbing, K., Herz, W., Hickford, S., Hilk, D., Hillesheimer, D., Howe, M. A., Huber, A., Jansen, A., Kellerer, J., Kernert, N., Kippenbrock, L., Kleesiek, M., Klein, M., Kopmann, A., Korzeczek, M., Kovalík, A., Krasch, B., Kraus, M., Kuckert, L., Lasserre, T., Lebeda, O., Letnev, J., Lokhov, A., Machatschek, M., Marsteller, A., Martin, E. L., Mertens, S., Mirz, S., Monreal, B., Neumann, H., Niemes, S., Off, A., Osipowicz, A., Otten, E., Parno, D. S., Pollithy, A., Poon, A. W. P., Priester, F., Ranitzsch, P. C. -O., Rest, O., Robertson, R. G. H., Roccati, F., Rodenbeck, C., Röllig, M., Röttele, C., Ryšavý, M., Sack, R., Saenz, A., Schimpf, L., Schlösser, K., Schlösser, M., Schönung, K., Schrank, M., Seitz-Moskaliuk, H., Sentkerestiová, J., Sibille, V., Slezák, M., Steidl, M., Steinbrink, N., Sturm, M., Suchopar, M., Suesser, M., Telle, H. H., Thorne, L. A., Thümmler, T., Titov, N., Tkachev, I., Trost, N., Valerius, K., Vénos, D., Vianden, R., Hernández, A. P. Vizcaya, Weber, M., Weinheimer, C., Weiss, C., Welte, S., Wendel, J., Wilkerson, J. F., Wolf, J., Wüstling, S., Zadoroghny, S.
المصدر: Eur. Phys. J. C (2018) 78:368
سنة النشر: 2018
المجموعة: Physics (Other)
مصطلحات موضوعية: Physics - Instrumentation and Detectors
الوصف: The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
Comment: 7 pages, 5 figures
نوع الوثيقة: Working Paper
DOI: 10.1140/epjc/s10052-018-5832-y
URL الوصول: http://arxiv.org/abs/1802.05227
رقم الأكسشن: edsarx.1802.05227
قاعدة البيانات: arXiv
الوصف
DOI:10.1140/epjc/s10052-018-5832-y