دورية أكاديمية

Prediction of Collapse Using Patient‐Specific Finite Element Analysis of Osteonecrosis of the Femoral Head

التفاصيل البيبلوغرافية
العنوان: Prediction of Collapse Using Patient‐Specific Finite Element Analysis of Osteonecrosis of the Femoral Head
المؤلفون: Tai‐xian Li, Ze‐qing Huang, Yan Li, Zhi‐peng Xue, Ji‐gao Sun, Huan‐huan Gao, Hai‐jun He, Wei‐heng Chen
المصدر: Orthopaedic Surgery, Vol 11, Iss 5, Pp 794-800 (2019)
بيانات النشر: Wiley, 2019.
سنة النشر: 2019
المجموعة: LCC:Orthopedic surgery
مصطلحات موضوعية: Osteonecrosis of the femoral head, Femoral head collapse prediction, Finite element analysis, Diagnostic test, Orthopedic surgery, RD701-811
الوصف: Objective To develop a prediction method for femoral head collapse by using patient‐specific finite element analysis of osteonecrosis of the femoral head (ONFH). Methods The retrospective study recruited 40 patients with ARCO stage‐II ONFH (40 pre‐collapse hips). Patients were divided into two groups according to the 1‐year follow‐up outcomes: patient group without femoral head collapse (noncollapse group, n = 20) and patient group with collapse (collapse group, n = 20). CT scans of the hip were performed for all patients once they joined the study. Patient‐specific finite element models were generated based on these original CT images following the same procedures: segmenting the necrotic lesion and viable proximal femur, meshing the computational models, assigning different material properties according to the Hounsfield unit distribution, simulating the stress loading of the slow walking gait, and measuring the distribution of the von Mises stress. Receiver operating characteristic (ROC) curve analysis was used to evaluate the predictive performance of the maximum level of the von Mises stress. The optimal cut‐off value was selected based on the Youden index and the corresponding predictive accuracy was reported as well. Results The mean level of the maximum von Mises stress in the collapse group was 2.955 ± 0.539 MPa, whereas the mean stress level in the noncollapse group was 1.923 ± 0.793 MPa (P
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1757-7861
1757-7853
Relation: https://doaj.org/toc/1757-7853; https://doaj.org/toc/1757-7861
DOI: 10.1111/os.12520
URL الوصول: https://doaj.org/article/02534adf8f3248de97b58e899988abe1
رقم الأكسشن: edsdoj.02534adf8f3248de97b58e899988abe1
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17577861
17577853
DOI:10.1111/os.12520