العنوان: Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for screening patients with imported malaria in a non-endemic setting
المؤلفون: Ponce Camille, Kaczorowski Flora, Perpoint Thomas, Miailhes Patrick, Sigal Alain, Javouhey Etienne, Gillet Yves, Jacquin Laurent, Douplat Marion, Tazarourte Karim, Potinet Véronique, Simon Bruno, Lavoignat Adeline, Bonnot Guillaume, Sow Fatimata, Bienvenu Anne-Lise, Picot Stéphane
المصدر: Parasite, Vol 24, p 53 (2017)
بيانات النشر: EDP Sciences, 2017.
سنة النشر: 2017
المجموعة: LCC:Infectious and parasitic diseases
مصطلحات موضوعية: Malaria, diagnosis, Plasmodium, isothermal amplification, LAMP, microscopy, Infectious and parasitic diseases, RC109-216
الوصف: Background: Sensitive and easy-to-perform methods for the diagnosis of malaria are not yet available. Improving the limit of detection and following the requirements for certification are issues to be addressed in both endemic and non-endemic settings. The aim of this study was to test whether loop-mediated isothermal amplification of DNA (LAMP) may be an alternative to microscopy or real-time PCR for the screening of imported malaria cases in non-endemic area. Results: 310 blood samples associated with 829 suspected cases of imported malaria were tested during a one year period. Microscopy (thin and thick stained blood slides, reference standard) was used for the diagnosis. Real-time PCR was used as a standard of truth, and LAMP (Meridian Malaria Plus) was used as an index test in a prospective study conducted following the Standards for Reporting Diagnosis Accuracy Studies. In the 83 positive samples, species identification was P. falciparum (n = 66), P. ovale (n = 9), P. vivax (n = 3) P. malariae (n = 3) and 2 co-infections with P. falciparum + P.malariae. Using LAMP methods, 93 samples gave positive results, including 4 false-positives. Sensitivity, specificity, positive predictive value and negative predictive value for LAMP tests were 100%, 98.13%, 95.51%, and 100% compared to PCR. Conclusion: High negative predictive value, and limit of detection suggest that LAMP can be used for screening of imported malaria cases in non-endemic countries when expert microscopists are not immediately available. However, the rare occurrence of non-valid results and the need for species identification and quantification of positive samples preclude the use of LAMP as a single reference method.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1776-1042
Relation: https://doaj.org/toc/1776-1042
DOI: 10.1051/parasite/2017054
URL الوصول: https://doaj.org/article/17cf7ff3ab4244ad84dde17e5b755eb4
رقم الأكسشن: edsdoj.17cf7ff3ab4244ad84dde17e5b755eb4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17761042
DOI:10.1051/parasite/2017054