دورية أكاديمية

Reproducibility and Robustness of a Liver Microphysiological System PhysioMimix LC12 under Varying Culture Conditions and Cell Type Combinations

التفاصيل البيبلوغرافية
العنوان: Reproducibility and Robustness of a Liver Microphysiological System PhysioMimix LC12 under Varying Culture Conditions and Cell Type Combinations
المؤلفون: Alicia Y. Lim, Yuki Kato, Courtney Sakolish, Alan Valdiviezo, Gang Han, Piyush Bajaj, Jason Stanko, Stephen S. Ferguson, Remi Villenave, Philip Hewitt, Rhiannon N. Hardwick, Ivan Rusyn
المصدر: Bioengineering, Vol 10, Iss 10, p 1195 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Technology
LCC:Biology (General)
مصطلحات موضوعية: microphysiological systems, liver, testing, tissue chip, Technology, Biology (General), QH301-705.5
الوصف: The liver is one of the key organs for exogenous and endogenous metabolism and is often a target for drug- and chemical-driven toxicity. A wide range of experimental approaches has been established to model and characterize the mechanisms of drug- and chemical-induced hepatotoxicity. A number of microfluidics-enabled in vitro models of the liver have been developed, but the unclear translatability of these platforms has hindered their adoption by the pharmaceutical industry; to achieve wide use for drug and chemical safety evaluation, demonstration of reproducibility and robustness under various contexts of use is required. One of these commercially available platforms is the PhysioMimix LC12, a microfluidic device where cells are seeded into a 3D scaffold that is continuously perfused with recirculating cell culture media to mimic liver sinusoids. Previous studies demonstrated this model’s functionality and potential applicability to preclinical drug development. However, to gain confidence in PhysioMimix LC12’s robustness and reproducibility, supplementary characterization steps are needed, including the assessment of various human hepatocyte sources, contribution of non-parenchymal cells (NPCs), and comparison to other models. In this study, we performed replicate studies averaging 14 days with either primary human hepatocytes (PHHs) or induced pluripotent stem cell (iPSC)-derived hepatocytes, with and without NPCs. Albumin and urea secretion, lactate dehydrogenase, CYP3A4 activity, and metabolism were evaluated to assess basal function and metabolic capacity. Model performance was characterized by different cell combinations under intra- and inter-experimental replication and compared to multi-well plates and other liver platforms. PhysioMimix LC12 demonstrated the highest metabolic function with PHHs, with or without THP-1 or Kupffer cells, for up to 10–14 days. iPSC-derived hepatocytes and PHHs co-cultured with additional NPCs demonstrated sub-optimal performance. Power analyses based on replicate experiments and different contexts of use will inform future study designs due to the limited throughput and high cell demand. Overall, this study describes a workflow for independent testing of a complex microphysiological system for specific contexts of use, which may increase end-user adoption in drug development.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 10101195
2306-5354
Relation: https://www.mdpi.com/2306-5354/10/10/1195; https://doaj.org/toc/2306-5354
DOI: 10.3390/bioengineering10101195
URL الوصول: https://doaj.org/article/a18304e2256b45029ba33d462bd66feb
رقم الأكسشن: edsdoj.18304e2256b45029ba33d462bd66feb
قاعدة البيانات: Directory of Open Access Journals