Estudo experimental da aplicação do ventrículo artificial eletromecânico pulsátil implantável Experimental study of pulsatile implantable electromechanical artificial ventricle

التفاصيل البيبلوغرافية
العنوان: Estudo experimental da aplicação do ventrículo artificial eletromecânico pulsátil implantável Experimental study of pulsatile implantable electromechanical artificial ventricle
المؤلفون: Jarbas Jakson Dinkhuysen, Aron Andrade, Carlos Conteras, Paulo Paredes Paulista, Juliana Leme, Ricardo Manrique
المصدر: Brazilian Journal of Cardiovascular Surgery, Vol 26, Iss 1, Pp 76-85 (2011)
بيانات النشر: Sociedade Brasileira de Cirurgia Cardiovascular, 2011.
سنة النشر: 2011
المجموعة: LCC:Surgery
LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: Insuficiência Cardíaca, Coração Artificial, Coração Auxiliar, Assistência de Longa Duração, Heart Failure, Heart, Artificial, Heart-Assist Devices, Long-Term Care, Surgery, RD1-811, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: OBJETIVO: Apresentar os resultados da aplicação deste dispositivo em animais de experimentação, promovendo auxílio hemodinâmico apenas ao ventrículo esquerdo (VE). MÉTODOS: Entre junho 2002 e outubro 2009, foram implantados em 27 bezerros com idade 2½ a 4 meses e peso 80/100 kg e, por meio de anestesia geral e ventilação controlada e de toracotomia lateral esquerda, era introduzida cânula no ápice do VE e anastomose término/lateral de tubo vascular de politetrafluoretileno (PTFE) com a porção descendente da aorta torácica, ambos interligados ao dispositivo implantado no subcutâneo abaixo do diafragma (24) e intratorácico (três). Em cinco bezerros, o dispositivo foi aplicado com auxílio de circulação extracorpórea (CEC) e, em 22, sem CEC. RESULTADOS: Ocorreram dois óbitos durante o implante e três por causas diversas nas primeiras horas de pós-operatório (PO), sendo um relacionado ao dispositivo. A sobrevivência entre o 1º e 6º dia de PO ocorreu em 17 animais e entre o 8º e 31º dia de PO em cinco, com causas determinantes diversas, não só por problemas clínico/cirúrgicos, mas também relacionados ao dispositivo. O impacto hemodinâmico avaliado pela análise da pressão sistêmica mostrou incremento que variou de 20 a 40 mmHg e os dados laboratoriais analisados demonstraram baixos impactos traumáticos à crase sanguínea e boa biocompatibilidade. CONCLUSÃO: Trata-se de pesquisa árdua e complexa onde a cada experimento são identificados problemas não só de implantabilidade, mas também relacionados ao dispositivo, que vão sendo sistematicamente corrigidos, tornando-o cada vez mais seguro e eficaz.OBJECTIVE: The objective is to present the results of the application this device in experimental animals unloading only the left ventricle. METHODS: Between June 2002 and October 2009, were implanted in 27 calfs with age between 2½ to 4 months and 80 to 100 kg of weight, with general anaesthesia and controled ventilation, by mean of left thoracotomy a cannula in the apex of VE and a lateral anastomose of a GTFE vascular graft tube in the descending portion of the thoracic aorta, both connected to the device implanted below the diaphragm in the subcutaneous (24) and intrathoracic (three). The cardiopulmonary bypass (BP) was used in five calves, and directly introduce the outflow cannula in 22. RESULTS: During the implant two and in the first hours of the post operative period (PO) three deaths were observed, one related to the device. The survival between the first and the six PO day was found in 17 calves and between day 8 and day 31 (PO) in five all caused by clinical/surgical problems, and related to the device. The hemodynamic impact by the systemic pressure analysis showed 20 to 40 mmHg increase and the laboratory parameters showed lower levels of traumatic impact to the blood and a good biocompatibility. CONCLUSIONS: This kind of research is arduous and complex where at each experiment many problems are indentified in the implantability and in the device, which are sistematic correct, to became device/procedure safe and effective.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0102-7638
1678-9741
Relation: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382011000100015; https://doaj.org/toc/0102-7638; https://doaj.org/toc/1678-9741
DOI: 10.1590/S0102-76382011000100015
URL الوصول: https://doaj.org/article/190d7ac4a5854e99ba9dcf72abccd7a9
رقم الأكسشن: edsdoj.190d7ac4a5854e99ba9dcf72abccd7a9
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:01027638
16789741
DOI:10.1590/S0102-76382011000100015