دورية أكاديمية

A Dynamic, Self-Tensioning Suture Contracts in Saline to Counteract Changes in Loop Length From Cyclic Loading

التفاصيل البيبلوغرافية
العنوان: A Dynamic, Self-Tensioning Suture Contracts in Saline to Counteract Changes in Loop Length From Cyclic Loading
المؤلفون: Nabil Mehta, M.D., Elizabeth Shewman, M.S., Sachin Allahabadi, M.D., Stanley Liu, M.A., Niraj V. Lawande, B.S., Burton Dunlap, M.D., Jorge Chahla, M.D., Gregory P. Nicholson, M.D., Grant E. Garrigues, M.D.
المصدر: Arthroscopy, Sports Medicine, and Rehabilitation, Vol 6, Iss 4, Pp 100872- (2024)
بيانات النشر: Elsevier, 2024.
سنة النشر: 2024
المجموعة: LCC:Sports medicine
مصطلحات موضوعية: Sports medicine, RC1200-1245
الوصف: Purpose: To compare the biomechanical performance of a suture with proposed dynamic self-tensioning properties with that of commonly used high-tensile sutures by evaluating suture loop length changes, responses to cyclic loading, and failure testing with intermittent saline soaks. Methods: Six knots each of 4 different sutures were studied: 3 high-tensile sutures (ORTHOCORD, FiberWire, and ETHIBOND), and a dynamically self-tensioning suture (DYNACORD). After we measured loop length, knots were soaked in 37°C saline for 24 hours. Loop lengths were remeasured and tensile testing was performed. Cyclic elongation, first-cycle excursion, and elongation amplitude were recorded. Knots were then resoaked and retested. Finally, knots were pulled to failure, and peak load and stiffness were measured. Values were compared using nonparametric statistical tests. Results: DYNACORD loop length decreased by 27% after the first soak (P = .002), whereas the other sutures demonstrated no length change (P > .05). Although DYNACORD loop length increased during cyclic load testing (P = .009), it was still significantly reduced after the second saline soak compared with its initial length (P = .002), whereas all other suture loops had elongated. ETHIBOND (P = .004) and ORTHOCORD (P = .002) had significantly less cyclic elongation from cycle I to cycle II testing compared with the other sutures. ETHIBOND had the lowest peak load at failure (P = .002). FiberWire had the greatest stiffness (P = .006). Conclusions: Compared with other suture types, the self-tensioning suture showed dynamic properties, demonstrating a decrease in loop length when soaked in a saline bath. This length was maintained after a second soak despite increased loop length during interval cyclic loading. Clinical Relevance: Knot and loop security are of paramount importance to arthroscopic soft-tissue procedures. The ability for a suture to self-tension has implications for how it may interact with tissues in vivo to increase construct stability after arthroscopic soft tissue repair procedures.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2666-061X
Relation: http://www.sciencedirect.com/science/article/pii/S2666061X23002237; https://doaj.org/toc/2666-061X
DOI: 10.1016/j.asmr.2023.100872
URL الوصول: https://doaj.org/article/293351cc94f849729f8ccc62ee86170f
رقم الأكسشن: edsdoj.293351cc94f849729f8ccc62ee86170f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2666061X
DOI:10.1016/j.asmr.2023.100872