Engineering Properties of Novel Vertical Cutoff Wall Backfills Composed of Alkali-Activated Slag, Polymer-Amended Bentonite and Sand

التفاصيل البيبلوغرافية
العنوان: Engineering Properties of Novel Vertical Cutoff Wall Backfills Composed of Alkali-Activated Slag, Polymer-Amended Bentonite and Sand
المؤلفون: Zheyuan Jiang, Xianlei Fu, Jianyong Shi, Chi Che, Yanjun Du
المصدر: Polymers, Vol 15, Iss 14, p 3059 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Organic chemistry
مصطلحات موضوعية: vertical cutoff wall backfill, polyacrylamide cellulose, hydraulic conductivity, strength, Organic chemistry, QD241-441
الوصف: The workability, hydraulic conductivity, and mechanical properties are essential to contaminant containment performance of cementitious backfills in vertical cutoff walls at contaminated sites. This study aims to investigate the engineering properties of a novel vertical cutoff wall backfill composed of reactive magnesia (MgO)-activated ground granulated blast furnace slag (GGBS), sodium-activated calcium bentonite amended with polyacrylamide cellulose (PAC), and clean sand (referred to as MSBS-PAC). Backfills composed of MgO-activated GGBS, sodium-activated calcium bentonite, and clean sand (referred to as MSBS) were also tested for comparison purposes. A series of tests were conducted which included slump test, flexible-wall hydraulic conductivity test, and unconfined compression test. The pore size distributions of two types of backfills were investigated via the nuclear magnetic resonance (NMR) technique. The results showed the moisture content corresponding to the target slump height was higher for MSBS-PAC backfill than that for MSBS backfill. The MSBS-PAC backfill possessed lower pH, dry density, and higher void ratio at different standard curing times as compared to MSBS backfill. The unconfined compressive strength and strain at failure of the MSBS-PAC backfill were noticeable lower than those of the MSBS backfill. In contrast, the hydraulic conductivity of MSBS-PAC backfill was approximately one order of magnitude lower than that of the MSBS backfill, which was less than 10−9 m/s after 28-day and 90-day curing. Lower hydraulic conductivity of MSBS-PAC backfill was attributed to the improvement of pore structure and pore fluid environment by PAC amendment.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2073-4360
Relation: https://www.mdpi.com/2073-4360/15/14/3059; https://doaj.org/toc/2073-4360
DOI: 10.3390/polym15143059
URL الوصول: https://doaj.org/article/ec2a03ef3e0345adaa0d0ede3366cd7f
رقم الأكسشن: edsdoj.2a03ef3e0345adaa0d0ede3366cd7f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20734360
DOI:10.3390/polym15143059