دورية أكاديمية

Synthetic ECG Signal Generation Using Probabilistic Diffusion Models

التفاصيل البيبلوغرافية
العنوان: Synthetic ECG Signal Generation Using Probabilistic Diffusion Models
المؤلفون: Edmonmd Adib, Amanda S. Fernandez, Fatemeh Afghah, John J. Prevost
المصدر: IEEE Access, Vol 11, Pp 75818-75828 (2023)
بيانات النشر: IEEE, 2023.
سنة النشر: 2023
المجموعة: LCC:Electrical engineering. Electronics. Nuclear engineering
مصطلحات موضوعية: Generative adversarial networks, wasserstein GAN, synthetic ECG generation, probabilistic diffusion model, improved denoising diffusion probabilistic models (DDPM), Electrical engineering. Electronics. Nuclear engineering, TK1-9971
الوصف: Deep learning image processing models have had remarkable success in recent years in generating high quality images. Particularly, the Improved Denoising Diffusion Probabilistic Models (DDPM) have shown superiority in image quality to the state-of-the-art generative models, which motivated us to investigate their capability in the generation of the synthetic electrocardiogram (ECG) signals. In this work, synthetic ECG signals are generated by the Improved DDPM and by the Wasserstein GAN with Gradient Penalty (WGAN-GP) models and then compared. To this end, we devise a pipeline to utilize DDPM in its original $2D$ form. First, the $1D$ ECG time series data are embedded into the $2D$ space, for which we employed the Gramian Angular Summation/Difference Fields (GASF/GADF) as well as Markov Transition Fields (MTF) to generate three $2D$ matrices from each ECG time series, which when put together, form a 3-channel $2D$ datum. Then $2D$ DDPM is used to generate $2D~3$ -channel synthetic ECG images. The $1D$ ECG signals are created by de-embedding the $2D$ generated image files back into the $1D$ space. This work focuses on unconditional models and the generation of Normal Sinus Beat ECG signals exclusively, where the Normal Sinus Beat class from the MIT-BIH Arrhythmia dataset is used in the training phase. The quality, distribution, and the authenticity of the generated ECG signals by each model are quantitatively evaluated and compared. Our results show that in the proposed pipeline and in the particular setting of this paper, the WGAN-GP model is consistently superior to DDPM in all the considered metrics.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2169-3536
Relation: https://ieeexplore.ieee.org/document/10185559/; https://doaj.org/toc/2169-3536
DOI: 10.1109/ACCESS.2023.3296542
URL الوصول: https://doaj.org/article/c30e1435a1f74e4f93088d23356a4462
رقم الأكسشن: edsdoj.30e1435a1f74e4f93088d23356a4462
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21693536
DOI:10.1109/ACCESS.2023.3296542