دورية أكاديمية

Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse

التفاصيل البيبلوغرافية
العنوان: Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse
المؤلفون: Silvio Kau, Katharina S. Motter, Viktoria J. Moser, João R. Kunz, Matteo Pellachin, Bettina Hartl
المصدر: Veterinary Sciences, Vol 9, Iss 9, p 481 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Veterinary medicine
مصطلحات موضوعية: equine, tooth angle, occlusal surface, incisor table angle, malocclusion, diagonal bite, Veterinary medicine, SF600-1100
الوصف: Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (MaPHorse1). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulting in 16 measures per examiner*head. Sagittal and transversal angle measures revealed low intraexaminer variability at scale-level independent mean SDs of α 0.58° and α 0.69°, respectively. Sagittal angle measures associate with low interexaminer variability, showing small mean angle differences (max. α 0.51° ± 0.35°), small scatter, and more consistent data reproducibility. Despite comparable mean interexaminer differences, the spread of transversal angle measures was relevantly higher using the proposed landmarks (average 2.2-fold higher interquartile range). The measurement performance of experienced and inexperienced examiners did not systematically differ. The time required for individual measurements was already comparable after 24/96 repetitions. This instrument may help deciphering sagittal angle normocclusal range and orthognathic dynamics and, with a proposed procedural amendment, transversal angle as well.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2306-7381
Relation: https://www.mdpi.com/2306-7381/9/9/481; https://doaj.org/toc/2306-7381
DOI: 10.3390/vetsci9090481
URL الوصول: https://doaj.org/article/366050ab5524478a98a463d2a26bcbd8
رقم الأكسشن: edsdoj.366050ab5524478a98a463d2a26bcbd8
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23067381
DOI:10.3390/vetsci9090481