دورية أكاديمية

Analysis of Geometric and Dosimetric Effects of Bra Application to Support Large or Pendulous Breasts During Radiotherapy Planning: A Retrospective Single-Center Study

التفاصيل البيبلوغرافية
العنوان: Analysis of Geometric and Dosimetric Effects of Bra Application to Support Large or Pendulous Breasts During Radiotherapy Planning: A Retrospective Single-Center Study
المؤلفون: So Hyun Park PhD, Jinhyun Choi MD
المصدر: Technology in Cancer Research & Treatment, Vol 20 (2021)
بيانات النشر: SAGE Publishing, 2021.
سنة النشر: 2021
المجموعة: LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Purpose: To evaluate geometric and dosimetric effects of bra application during radiotherapy planning for breast cancer patients with large and pendulous breasts. Materials and Methods: Twenty patients with chest sizes >38 inches between April 2019 and July 2019 underwent radiotherapy planning with and without a radiation bra (Chabner XRT ® ). Geometric and dosimetric parameters included the breast volume, superior-inferior (SI) distance, separation (S) as the distance of the longest diameter of the clinical target volume (CTV), conformity number (CN), and homogeneity index (HI) of CTV. The organs at risk (OARs) were defined as the lungs, heart, and liver. Results: The use of the radiation bra provided mean changes of −0.51 cm for S, −1.45 cm for SI, and −61.18 cc for breast volume (all P < 0.05). Breast volume was correlated with bra-related changes in cross diameter (r = 0.641, P = 0.002) and volume (r = 0.680, P = 0.001). Significant dose reductions were observed for the lungs (mean V 10 : 19.58 cc, V 20 : 17.13 cc, D mean : 86.24 cGy) and heart (D mean : 170.23 cGy). No significant differences were observed for CN (0.62-0.67) and HI (0.19-0.20) of the CTV. Conclusion: The application of a radiation bra was associated with better geometric and dosimetric planning parameters, with a smaller CTV and lower doses to the OARs (lungs and heart) in the radiotherapy field. In addition, we expect that bra use during radiotherapy would provide emotional benefits.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1533-0338
15330338
Relation: https://doaj.org/toc/1533-0338
DOI: 10.1177/15330338211027909
URL الوصول: https://doaj.org/article/39f59276fb3d4519b59caede0a00c277
رقم الأكسشن: edsdoj.39f59276fb3d4519b59caede0a00c277
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:15330338
DOI:10.1177/15330338211027909