دورية أكاديمية

Global biomarkers of oxidative stress and fractures: a matched case-control study

التفاصيل البيبلوغرافية
العنوان: Global biomarkers of oxidative stress and fractures: a matched case-control study
المؤلفون: Shuman Yang, Lijie Feng, Lisa M. Lix, William D. Leslie, Dingjie Guo, Xianbao Shi, Baoming Yuan
المصدر: Frontiers in Endocrinology, Vol 14 (2023)
بيانات النشر: Frontiers Media S.A., 2023.
سنة النشر: 2023
المجموعة: LCC:Diseases of the endocrine glands. Clinical endocrinology
مصطلحات موضوعية: oxidative stress, fluorescent oxidation products, osteoporosis, fracture, Chinese, hip fractures, Diseases of the endocrine glands. Clinical endocrinology, RC648-665
الوصف: BackgroundEvidence for a relationship between oxidative stress and osteoporotic fractures in humans is limited. Fluorescent oxidation products (FlOPs, excitation/emission wavelengths 320/420nm denoted FlOP_320; 360/420nm [FlOP_360]; and 400/475nm [FlOP_400]) are global biomarkers of oxidative stress, and reflect oxidative damage to proteins, phospholipids, and nucleic acids. We investigated the association between FlOPs and a recent osteoporotic fracture.MethodsWe conducted a case-control study in a Chinese population aged 50 years or older. A recent osteoporotic fracture in the cases was confirmed by x-ray. Cases were matched with community-based non-fracture controls (1:2 ratio) for age (± 4 years) and sex. In addition, we conducted a sensitivity unmatched case-control study which included all fracture cases and all eligible non-fracture controls prior to matching. Plasma FlOPs were measured with a fluorescent microplate reader. We used unconditional logistic regression to analyze the association between FlOPs (per 1-SD increase in logarithmic scale) and fracture; odds ratios (OR) and 95% confidence intervals (95% CI) were reported.ResultsForty-four cases and 88 matched controls (mean age: 68.2 years) were included. After covariate adjustment (i.e., body mass index, physical activity, and smoking), higher FlOP_360 (OR = 1.85; 95% CI = 1.03 – 3.34) and FlOP_400 (OR = 13.29; 95% CI = 3.48 – 50.69) levels, but not FlOP_320 (OR = 0.56; 95% CI = 0.27 – 1.15), were associated with increased fracture risk. Subgroup analyses by fracture site and unmatched case-control study found comparable associations of FlOP_360 and FlOP_400 with hip and non-hip fractures.ConclusionsHigher FlOP_360 and FlOP_400 levels were associated with increased risk of fracture, and this association was comparable for hip and non-hip fractures. Prospective studies are warranted to confirm this finding.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1664-2392
Relation: https://www.frontiersin.org/articles/10.3389/fendo.2023.1179521/full; https://doaj.org/toc/1664-2392
DOI: 10.3389/fendo.2023.1179521
URL الوصول: https://doaj.org/article/3b974fbb803345f6a42d074441455bcb
رقم الأكسشن: edsdoj.3b974fbb803345f6a42d074441455bcb
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16642392
DOI:10.3389/fendo.2023.1179521