الوصف: Abstract Background Prompt and accurate diagnosis of prostate cancer (PCa) is of paramount importance for effective treatment planning. While Gallium-68 labeled prostate-specific membrane antigen (PSMA) positron emission tomography (PET)/computed tomography (CT) has proven efficacy in detecting PCa, limited availability poses challenges. As a potential alternative, [99mTc]Tc-PSMA single photon emission computed tomography (SPECT)/computed tomography (CT) holds promise. This systematic review and meta-analysis aimed to evaluate the diagnostic value of [99mTc]Tc-PSMA SPECT/CT for prostate cancer. Methods A comprehensive search of PubMed, Cochrane, EMBASE, Scopus, Ovid, and Web of Science databases was conducted until July 2024. Sensitivity and specificity data were extracted to assess the diagnostic accuracy of [99mTc]Tc-PSMA SPECT/CT, while the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to evaluate study quality. Statistical analyses were performed using STATA 18, with MetaDisc 1.4 employed to detect threshold effects. Diagnostic accuracy indicators, including sensitivity, specificity, diagnostic odds ratio (DOR), negative likelihood ratio (LR-), and positive likelihood ratio (LR+), were pooled. The area under the curve (AUC) of the combined model was calculated using summary receiver-operating characteristic (SROC) curves. Results Seven studies meeting the inclusion criteria were identified from an initial pool of 1467 articles, with no publication bias observed. The pooled sensitivity, specificity, and AUC of [99mTc]Tc-PSMA SPECT/CT were found to be 0.89 (95% CI, 0.84–0.93), 0.92 (95% CI, 0.67–0.99), and 0.93 (95% CI, 0.90–0.95), respectively. Additionally, the comprehensive diagnostic odds ratio, diagnostic score, positive likelihood ratio, and negative likelihood ratio were calculated as 95.24 (95% CI, 17.30-524.41), 4.56 (95% CI, 2.85–6.26), 11.35 (95% CI, 2.31–55.71), and 0.12 (95% CI, 0.08–0.18), respectively. Conclusions In conclusion, our findings demonstrate that [99mTc]Tc-PSMA SPECT/CT exhibits favorable diagnostic performance for prostate cancer and can provide valuable supplementary information, particularly in regions and settings where [68Ga]Ga-PSMA PET/CT availability is limited, such as remote areas. These results highlight the potential of [99mTc]Tc-PSMA SPECT/CT as a valuable tool in the diagnosis and management of prostate cancer, warranting further investigation and validation in larger patient cohorts.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2407
Relation: https://doaj.org/toc/1471-2407
DOI: 10.1186/s12885-024-12734-4
URL الوصول: https://doaj.org/article/3ba87c18f19e455a84b44cd1dc4bfae5
رقم الأكسشن: edsdoj.3ba87c18f19e455a84b44cd1dc4bfae5
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712407
DOI:10.1186/s12885-024-12734-4