دورية أكاديمية

Assessment of a Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Pathogenic Bacteria from Respiratory Samples in Patients with Hospital-Acquired Pneumonia

التفاصيل البيبلوغرافية
العنوان: Assessment of a Loop-Mediated Isothermal Amplification (LAMP) Assay for the Rapid Detection of Pathogenic Bacteria from Respiratory Samples in Patients with Hospital-Acquired Pneumonia
المؤلفون: Andrea Vergara, Hervé Boutal, Adrián Ceccato, Míriam López, Adrià Cruells, Leticia Bueno-Freire, Javier Moreno-Morales, Jorge Puig de la Bellacasa, Pedro Castro, Antoni Torres, Francesc Marco, Climent Casals-Pascual, Jordi Vila
المصدر: Microorganisms, Vol 8, Iss 1, p 103 (2020)
بيانات النشر: MDPI AG, 2020.
سنة النشر: 2020
المجموعة: LCC:Biology (General)
مصطلحات موضوعية: loop-mediated isothermal amplification (lamp), hospital-acquired pneumonia (hap), diagnostic techniques, respiratory system, critical care, Biology (General), QH301-705.5
الوصف: Rapid identification of the causative agent of hospital-acquired pneumonia (HAP) will allow an earlier administration of a more appropriate antibiotic and could improve the outcome of these patients. The aim of this study was to develop a rapid protocol to identify the main microorganisms involved in HAP by loop-mediated isothermal amplification (LAMP) directly from respiratory samples. First of all, a rapid procedure (Staphylococcus aureus, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Stenotrophomonas maltophilia and Acinetobacter baumannii was performed with the extracted solution at 65 °C for 30−40 min. Overall, 58 positive BAL and 83 EA/BAS samples were tested. The limits of detection varied according to the microorganism detected. Validation of the LAMP assay with BAL samples showed that the assay was 100% specific and 86.3% sensitive (positive predictive value of 100% and a negative predictive value of 50%) compared with culture. Meanwhile for BAS/EA samples, the assay rendered the following statistical parameters: 100% specificity, 94.6% sensitivity, 100% positive predictive value and 69.2% negative predictive value. The turnaround time including sample preparation and LAMP was circa 1 h. LAMP method may be used to detect the most frequent bacteria causing HAP. It is a simple, cheap, sensitive, specific and rapid assay.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2076-2607
Relation: https://www.mdpi.com/2076-2607/8/1/103; https://doaj.org/toc/2076-2607
DOI: 10.3390/microorganisms8010103
URL الوصول: https://doaj.org/article/3bfe67bd0f6c4693ab28cb9b464b7147
رقم الأكسشن: edsdoj.3bfe67bd0f6c4693ab28cb9b464b7147
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20762607
DOI:10.3390/microorganisms8010103