Evaluating the Safety of Simultaneous Intracranial Electroencephalography and Functional Magnetic Resonance Imaging Acquisition Using a 3 Tesla Magnetic Resonance Imaging Scanner

التفاصيل البيبلوغرافية
العنوان: Evaluating the Safety of Simultaneous Intracranial Electroencephalography and Functional Magnetic Resonance Imaging Acquisition Using a 3 Tesla Magnetic Resonance Imaging Scanner
المؤلفون: Yuya Fujita, Hui Ming Khoo, Miki Hirayama, Masaaki Kawahara, Yoshihiro Koyama, Hiroyuki Tarewaki, Atsuko Arisawa, Takufumi Yanagisawa, Naoki Tani, Satoru Oshino, Louis Lemieux, Haruhiko Kishima
المصدر: Frontiers in Neuroscience, Vol 16 (2022)
بيانات النشر: Frontiers Media S.A., 2022.
سنة النشر: 2022
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: MRI, simultaneous intracranial EEG-fMRI, subdural electrode, depth electrode, 3 tesla, fMRI, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: BackgroundThe unsurpassed sensitivity of intracranial electroencephalography (icEEG) and the growing interest in understanding human brain networks and ongoing activities in health and disease have make the simultaneous icEEG and functional magnetic resonance imaging acquisition (icEEG-fMRI) an attractive investigation tool. However, safety remains a crucial consideration, particularly due to the impact of the specific characteristics of icEEG and MRI technologies that were safe when used separately but may risk health when combined. Using a clinical 3-T scanner with body transmit and head-receive coils, we assessed the safety and feasibility of our icEEG-fMRI protocol.MethodsUsing platinum and platinum-iridium grid and depth electrodes implanted in a custom-made acrylic-gel phantom, we assessed safety by focusing on three factors. First, we measured radio frequency (RF)-induced heating of the electrodes during fast spin echo (FSE, as a control) and the three sequences in our icEEG-fMRI protocol. Heating was evaluated with electrodes placed orthogonal or parallel to the static magnetic field. Using the configuration with the greatest heating observed, we then measured the total heating induced in our protocol, which is a continuous 70-min icEEG-fMRI session comprising localizer, echo-planar imaging (EPI), and magnetization-prepared rapid gradient-echo sequences. Second, we measured the gradient switching-induced voltage using configurations mimicking electrode implantation in the frontal and temporal lobes. Third, we assessed the gradient switching-induced electrode movement by direct visual detection and image analyses.ResultsOn average, RF-induced local heating on the icEEG electrode contacts tested were greater in the orthogonal than parallel configuration, with a maximum increase of 0.2°C during EPI and 1.9°C during FSE. The total local heating was below the 1°C safety limit across all contacts tested during the 70-min icEEG-fMRI session. The induced voltage was within the 100-mV safety limit regardless of the configuration. No gradient switching-induced electrode displacement was observed.ConclusionWe provide evidence that the additional health risks associated with heating, neuronal stimulation, or device movement are low when acquiring fMRI at 3 T in the presence of clinical icEEG electrodes under the conditions reported in this study. High specific absorption ratio sequences such as FSE should be avoided to prevent potential inadvertent tissue heating.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1662-453X
Relation: https://www.frontiersin.org/articles/10.3389/fnins.2022.921922/full; https://doaj.org/toc/1662-453X
DOI: 10.3389/fnins.2022.921922
URL الوصول: https://doaj.org/article/c4f2517284a14c27abf518ff2c9fa868
رقم الأكسشن: edsdoj.4f2517284a14c27abf518ff2c9fa868
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1662453X
DOI:10.3389/fnins.2022.921922