دورية أكاديمية

Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis

التفاصيل البيبلوغرافية
العنوان: Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
المؤلفون: Yasunobu Yamashita, Kensuke Tanioka, Yuki Kawaji, Takashi Tamura, Junya Nuta, Keiichi Hatamaru, Masahiro Itonaga, Takeichi Yoshida, Yoshiyuki Ida, Takao Maekita, Mikitaka Iguchi, Masayuki Kitano
المصدر: Gut and Liver, Vol 14, Iss 5, Pp 659-664 (2020)
بيانات النشر: Gastroenterology Council for Gut and Liver, 2020.
سنة النشر: 2020
المجموعة: LCC:Diseases of the digestive system. Gastroenterology
مصطلحات موضوعية: pancreatitis, chronic, shear wave eus elastography, rosemont classification, diabetes mellitus, Diseases of the digestive system. Gastroenterology, RC799-869
الوصف: Background/Aims: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been extensively studied yet. This study evaluated the utility of EUS-SWM for diagnosing CP and estimating CP severity by determining the presence of endocrine dysfunction along with diabetes mellitus (DM). Methods: Between June 2018 and December 2018, 52 patients who underwent EUS and EUS-SWM were classified into two groups according to RC: non-CP (indeterminate CP and normal) and CP (consistent and suggestive of CP). The EUSSWM value by shear wave velocity was evaluated with a median value. The EUS-SWM value was compared with RC and the number of EUS features. The diagnostic accuracy and cutoff value of EUS-SWM for CP and DM and its sensitivity and specificity were calculated. Results: The EUS-SWM value significantly positively correlated with the RC and the number of EUS features. The EUS-SWM values that were consistent and suggestive of CP were significantly higher than that of normal. The area under the receiver operating characteristic (AUROC) curve for the diagnostic accuracy of EUS-SWM for CP was 0.97. The cutoff value of 2.19 had 100% sensitivity and 94% specificity. For endocrine dysfunction in CP, the AUROC was 0.75. The cutoff value of 2.78 had 70% sensitivity and 56% specificity. Conclusions: EUS-SWM provides an objective assessment and can be an alternative diagnostic tool for diagnosing CP. EUS-SWM may also be useful for predicting the presence of endocrine dysfunction.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1976-2283
Relation: http://gutnliver.org/journal/view.html?doi=10.5009/gnl19170; https://doaj.org/toc/1976-2283
DOI: 10.5009/gnl19170
URL الوصول: https://doaj.org/article/56283457f67640c58127aebcd5fb16c0
رقم الأكسشن: edsdoj.56283457f67640c58127aebcd5fb16c0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19762283
DOI:10.5009/gnl19170