دورية أكاديمية

Bacterial concentration and Campylobacter spp. quantification differ when fresh or ultra-frozen samples are analysed over time using molecular biology and culture-based methods.

التفاصيل البيبلوغرافية
العنوان: Bacterial concentration and Campylobacter spp. quantification differ when fresh or ultra-frozen samples are analysed over time using molecular biology and culture-based methods.
المؤلفون: Farina Khattak, Salvatore Galgano, Jos Houdijk
المصدر: PLoS ONE, Vol 17, Iss 9, p e0274682 (2022)
بيانات النشر: Public Library of Science (PLoS), 2022.
سنة النشر: 2022
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: The study aimed to delineate the robustness of the culture-based and molecular biology methods to assess the total bacterial concentration and Campylobacter jejuni (C. jejuni) quantification in caecal content, analysed as fresh or after being stored immediately at ultra-low (-80°C) temperature at different time points (for 3, 7, 14, 28 and 62 days post collection). The caecal content was collected from birds that were artificially colonised with C. jejuni (in-vivo), and quantification was performed using both colony-forming unit (CFU) and qPCR. The results showed that storage time affected the output of culture-based analyses but mostly did not alter concentration retrieved via qPCR. After an initial ~4.5 log10 reduction in CFU observed from fresh (day 0) to frozen samples, bacterial concentration retrieved with culture-based methods seemed to be constant in samples frozen for 3 to 62 days, indicating a possible threshold for C. jejuni loss of viability due to effect of storage temperature. Ranking order analyses, revealed that the molecular biology technique was able to attribute somewhat the same relative C. jejuni concentrations to the samples analysed via qPCR. However, day 0 measurements from culture-based methods were associated with the absence of or negatively weak correlations with the rest of the time points, but ranking order was maintained from day 3 onwards. On the other hand, ranking order correlations were less constant when measuring total bacterial concentration through qPCR. The study suggests that if biological samples can't be analysed as fresh (immediately after collection) and have to be stored prior to analysis, then storage at -80°C samples be recommended to avoid the temporal-dependent effects on C. jejuni concentrations. In addition, irrespective of the method of analysis, an initial loss of CFU must be factored in when interpreting the results obtained from frozen samples.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
02997878
Relation: https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0274682
URL الوصول: https://doaj.org/article/5c16274c253f4c02997878811d50a80d
رقم الأكسشن: edsdoj.5c16274c253f4c02997878811d50a80d
قاعدة البيانات: Directory of Open Access Journals